Further information for Ifm Electronic AC2027 - AirBox interface FC SC lower parts
Accessories
Optional accessories
Silencer: E75232
Approvals / tests
EMC
EN 62026-2; EN IEC 61000-6-2; EN IEC 61000-6-4; EN IEC 61326-1
AS-i parameters
AS-i Master profile
M2; M3; M4
AS-i profile
S-3.F.F
AS-i I/O configuration
3 hex
AS-i ID code
F.F hex
Data bit assignment
Data bit / D0 / D1 / D2 / D3; Inputs/outputs / I-1 / I-2 / O-3 / O-4
Extended addressing mode
Displays / controls
Indication
Operation / LED, green (AS-i); Switching state / LED, yellow (I1...I2, O3...O4)
Electrical connection
Module connection
Flat cable
Electrical connection - Socket I-1
Plug connection
M12; coding: A; contacts: 4
Electrical data
Operating voltage
26,5...31,6 DC V
Max. current draw from AS-i
150 mA
Integrated watchdog
Environmental conditions
Ambient temperature
0...55 °C
Note on ambient temperature
With special compressed air treatment: < 0 °C; At ambient temperatures > 50 °C, derating of current loading capacity must be considered as per operating instructions
Storage temperature
-20...80 °C
Maximum permissible relative humidity
90; (non-condensing) %
Maximum height above sea level
2000 m
Degree of protection
IP 67
Pollution degree
2
Field of application
Application
Field mounting; For use in wet environments
Inputs
Number of digital inputs
2
Input circuitry for digital inputs
PNP
Sensor supply for inputs
AS-i
Power supply
20...30 V
Max. current rating inputs total
100 mA
Input current high
> 3 mA
Input current Low
< 1,5 mA
High switching level
> 10 V
Short-circuit resistance digital inputs
Inputs / Outputs
Number of inputs and outputs
Number of digital inputs: 2; Number of pneumatic outputs: 2
Mechanical data
Housing
rectangular
Mounting method
AS-i interface to FK- or PG subunits
Dimensions
45 x 80 x 47 mm
Materials
Housing: PBT
Pneumatic system
2 x 3/2-way seat valves
Operating pressure range
2...8 bar
Note on operating pressure range
including possible pressure peaks
Air volume at 6/5 bar
350 l/min
Air volume at 6/0 bar
550 l/min
Compressed air consistency
filtered (5 µm); oiled (ISO-VG10) or un-oiled
Hose connector
Legris LF 3000/8
Exhaust air ducting
Exhaust air can be discharged via hose connection
Outputs
Number of pneumatic outputs
2
Actuator supply for outputs
AS-i
Remarks
Remarks
Please note the instructions regarding compressed air and EMC/ESD under "Downloads"
AS-i AirBox, AS-i interface to FC and SC lower parts, 2 inputs / 2 outputs, Connection to the pneumatic system by tube fittings, 2 digital inputs, Sockets M12 x 1, 2 pneumatic outputs
Operating voltage: 26.5...31.6 V DC
Electrical design: 2 inputs / 2 outputs
Output function: common exhaust with tube connection
Total current consumption from AS-i: < 150 mA
Circuit: PNP
Sensor supply: AS-i
Voltage range: 20...30 DC V
Outputs:
Pneumatic system: two 3/2-way valves
Operating pressure range: 2...8 [bar]
Connection: contact pins on FC or SC lower module
Housing materials: PBT
Ambient temperature: 0...55, use below 0 °C possible with a special compressed air treatment °C
Protection: IP 67
Operation: LED green
Function display: LED yellow