Further information for Ifm Electronic AC1254 - Power supply power supply 115/230 AC
Approvals / tests
EMC
EN 61000-6-1; EN 61000-6-2; EN 61000-6-4
Vibration resistance
IEC 60068-2-6 / ± 1.6 mm 2...17.8 Hz / 2 g 17.8...500 Hz
Shock resistance
IEC 60068-2-27 / 30 g 6 ms / 20 g 11 ms
MTTF
90 years
AS-i parameters
AS-i certificate
98601
Displays / controls
Indication
AS-i voltage / LED, green
Electrical data
AC frequency
47...64 Hz
Operating voltage tolerance
10 %
Operating voltage
Automatic voltage range switching V
Nominal voltage AC
110 / 230 V
Input voltage range AC
100...120 / 200...240 V
Protection class
I
Over voltage protection
ja; (< 36 V)
Max. standby delay time
900 ms
Output voltage AS-i
30,5 V
Output power (continuous)
122 W
Output power (temporary)
134 W
Note on output power (temporary)
Briefly, for charging the bus capacitances after power-on W
Power factor (rated voltage 120 V AC / 60 Hz)
0,56
Power factor (rated voltage 230 V AC / 50 Hz)
0,47
Power reserve
10 %
Number of output circuits
1
Output current AS-i
4 A
Max. ripple
50 mV
Inrush current (rated voltage 120 V AC / 60 Hz)
3 A
Inrush current at rated voltage 230 V AC / 50 Hz
3 A
Efficiency (rated voltage 120 V AC / 60 Hz)
88 %
Efficiency (rated voltage 230 V AC / 50 Hz)
89,3 %
External input fuse
≤ B-10 A / ≤ C-6 A
Derating
3 (60...70 °C) W/K
Power failure bridging time (nominal voltage 120 V AC / 60 Hz)
70 ms
Power failure bridging time (rated voltage 230 V AC / 50 Hz)
70 ms
Input current (rated voltage 120 V AC / 60 Hz)
2,05 A
Input current (rated voltage 230 V AC / 50 Hz)
1,23 A
Power loss (rated voltage 120 V AC / 60 Hz)
16,6 W
Power loss (rated voltage 230 V AC / 50 Hz)
14,6 W
Reverse voltage withstand
35 V
Inrush current limitation
Integrated data decoupling
Environmental conditions
Ambient temperature
-25...70 °C
Note on ambient temperature
Allow for free spaces for convection (see operating instructions)
Storage temperature
-40...85 °C
Maximum permissible relative humidity
95; (IEC 60068-2-30) %
Degree of protection
IP 20
Pollution degree
2; (IEC 62103: conductive pollution not permitted)
Field of application
Model
DIN rail housing
Mechanical data
Housing
rectangular
Mounting method
DIN rail mounting; (TH35 (EN 60715))
Dimensions
130,5 x 40 x 124,5 mm
Materials
steel sheet
Outputs
Overload behaviour
constant output current
Short-circuit-proof
Overload resistant
Parallel connection of outputs possible
Series connection of outputs possible
Power supply, AS-i power supply 115/230 V AC, Integrated data decoupling, AS-i switch power supplies
Application: AS-i system voltage for masters, sensors, actuators and modules
Nominal voltage: 115 / 230 AC V
Nominal frequency: 50 / 60 Hz
Efficiency: 88 (120 V AC; 60 Hz) / 89.3 (230 V AC; 50 Hz) %
Connection: screw terminals
Housing materials: steel sheet
Ambient temperature: -25...70, observe the free space for convection (see operating instructions) °C
Protection: IP 20
Function display: LED green (indication AS-i voltage)
Accessories (to be ordered separately): Mounting accessories