Further information for Helukabel 89970 - HELU UL/CSA JZ 602 RC CY 4G1 5qmm (16AWG) Black drag chain cable PVC
Technical data:
Special PVC hose cable in accordance with UL CSA AWM I/II A/B Style 2587 (jacket material) and CSA
Temperature range moving -5°C to +90°C fixed -40°C to +90°C (briefly +105°C)
Nominal voltage UL/CSA 600 V
Test voltage 4000 V
Breakdown voltage min. 8000 V
Insulation resistance min. 20 MOhm x km
Minimum bending radius moving 10x cable Ø fixed 5x cable Ø
Radiation resistance up to 80x106 cJ/kg (up to 80 Mrad)
Coupling resistance max. 250 Ohm/km
Structure:
Bare copper conductor, super-fine stranded in accordance with DIN VDE 0295 cl.6, column 4, BS 6360 cl.6 or IEC 60228 cl.6
Core insulation made of special PVC Mixture type YI8 according to DIN VDE 0207 Part 4 and class 43 according to UL Std.1581
Core identification according to DIN VDE 0293 red cores with continuous white numbering
Cores stranded with optimal lay lengths
Fleece wrapping over each stranding layer
PVC inner jacket
Shielding: coverage approx. 85% up to 17 mm Ø - Cu wrapping >17 mm Ø - Cu braid,
outer jacket made of special PVC Mixture type YM5 according to DIN VDE 0207 Part 5, UL Style 2587 and CSA C22.2 No 210
Jacket color: black (RAL 9005) with meter marking
Properties:
The materials used in production are silicone and cadmium-free and free from substances that impair paint wetting
Tests:
PVC self-extinguishing and flame-retardant according to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1 , UL VW-1, CSA FT1
UV-resistant
Notes:
unshielded Analogue type: JZ-602 RC
Use:
For installation in dry, damp and wet rooms with free movement without tensile stress and without forced movement control as a shielded, highly flexible PVC control cable suitable for frequent lifting and bending stress in machine and tool construction, in robot technology and on permanently moving machine parts. Convincingly proven in standard drag chain use. The high shielding density ensures interference-free transmission of signals and impulses. The ideal interference-protected control cable for the above purposes. Interesting for export-oriented machine plant construction. For applications that go beyond standard solutions, we recommend our specially developed data collection form for energy supply systems. For further application parameters, see the selection table: Cables for energy supply chains in the introduction. For use in energy supply chains, please observe the assembly instructions. EMC = Electromagnetic Compatibility To optimize the EMC properties, we recommend contacting the copper braid on both sides and over a large area all around. RC = Robotics Cable
Standard lengths: 100 m, 500 m, 1000 m
Technical changes reserved.