Further information for Helukabel 83672 control cable 3G1,0 mm² grey
General
Degree of protection
oil-resistant
Temperature range
-5°C to +70°C moving, -40°C to +70°C non-moving (HAR); -5°C to +90°C moving, -40°C to +90°C non-moving (UL/CSA)
Nominal voltage
300/500 V (HAR), 600 V (UL/CSA)
Test voltage
3000 V
Dielectric strength
min. 6000 V
Insulation resistance
min. 20 MOhm x km
Minimum bending radius
7.5x cable Ø moving, 4x cable Ø non-moving
Radiation resistance
up to 80x106 cJ/kg (80 Mrad)
Conductor marking
black conductors with continuous white digit marking
Outer sheath
oil-resistant special PVC, grey (RAL 7001), with meter marking
Cu stranded wire
Bare, DIN VDE 0295 Class 5, fine-stranded
PVC insulation
Special PVC, Class 43 according to UL Std.1581
Oil resistance
according to DIN VDE 0473-811-404 / DIN EN 60811-404, UL-Std.1581 Part 50.182
Flame retardancy
Self-extinguishing, DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2, UL VW-1, CSA FT1
Standards
DIN VDE 0285-525-2-51, DIN EN 50525-2-51, UL Style 2587
Meter marking
The Helukabel control cable type 83672 is a special PVC hose cable with an oil-resistant outer sheath, designed for use in machines, plants, and devices intended for export. The cable complies with several international standards, including DIN VDE 0285-525-2-51, DIN EN 50525-2-51, and UL Style 2587, enabling worldwide use under moderate mechanical stress. It is suitable for flexible applications with free movement without tensile stress and without forced movement guidance, particularly in dry, damp, and wet indoor environments, but not for outdoor use. The cable is supplied in standard lengths of 100 m, 500 m, and 1000 m.
Applications
Control cable 83672 is used in industrial environments where high mechanical and chemical resistance is required. It is suitable for use in machine building, material handling technology, packaging technology, and other areas where control and signal transmission over short to medium distances is necessary. The multiple approvals according to international standards make it particularly suitable for export, as it can be used in many countries without additional testing.
Functions and equipment in detail
The cable consists of bare Cu stranded conductors according to DIN VDE 0295 Class 5, which are fine-stranded and thus ensure high flexibility. The conductors are insulated with special PVC, corresponding to Class 43 according to UL Std.1581. Conductor identification follows DIN VDE 0293 with black conductors and a continuous white digit print, enabling clear identification of individual conductors. The conductors are stranded in layers, with optimal lay lengths to minimize mechanical stress. The outer sheath is made of oil-resistant special PVC, also Class 43 according to UL Std.1581, and has a gray color (RAL 7001) with meter marking, facilitating accurate length determination.
Technology explained simply
The materials used are silicone- and cadmium-free and free from substances that could impair paint adhesion. This is particularly important in the painting and coating industry, where the cable is used near painting processes. The PVC insulation is self-extinguishing and flame-retardant, according to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2, UL VW-1, and CSA FT1, increasing operational safety. Oil resistance according to DIN VDE 0473-811-404 and UL-Std.1581 Part 50.182 protects the cable from wear caused by mineral oils and fats. Radiation resistance up to 80x106 cJ/kg (80 Mrad) makes the cable suitable for applications in environments with ionizing radiation.
Compatibility and accessories
Control cable 83672 is compatible with a wide range of connectors, cable lugs, and other mounting components designed for PVC insulation. A shielded variant designated JZ-603-CY is available if electromagnetic shielding is required. The cable can be used in combination with other control cables and cables in machine building, with the mechanical and electrical properties of 83672 facilitating integration into existing systems.
Installation and mounting
Mounting must consider the specified minimum bending radii: for moving applications, the radius is 7.5 times the cable Ø; for non-moving applications, 4 times. The cable must not be installed under tensile stress, and forced movement guidance is not permitted. Installation is carried out in dry, damp, and wet indoor environments, with outdoor use excluded. The meter marking facilitates accurate positioning and length measurement during installation.
Advantages in operation
Control cable 83672 offers high reliability under moderate mechanical stress. The combination of oil-resistant outer sheath, flame-retardant PVC, and high radiation resistance ensures long service life and low maintenance. Clear conductor identification and meter marking support quick installation and maintenance. Multiple approvals according to international standards reduce complexity when certifying machines and plants for export.
Protection rating, temperature range, rated voltage, insulation resistance, test voltage, breakdown voltage, minimum bending radius, radiation resistance, conductor identification, outer sheath, Cu stranded conductor, PVC insulation, oil resistance, flame retardancy, meter marking are the central technical features determining the functionality and suitability of the cable. The cable is designed for industrial applications where high mechanical, chemical, and thermal stresses may occur.