Further information for Helukabel 707295 - HELU TOPSERV® 119 PVC 4G10 (2x1) (2x1 5)) Orange UL/CSA
Technical data:
Special PVC motor cable according to UL AWM Style 2570 CSA AWM VDE registered
Temperature range moving -0°C to +60°C fixed -20°C to +80°C
Nominal voltage VDE U0/U 600/1000 V UL/CSA 1000 V
Test alternating voltage, 50 Hz 4000 V
Minimum bending radius moving 15x cable Ø fixed 5x cable Ø min. 100,000 cycles
Structure: Bare copper
wire, according to DIN EN 60228 Class 5: fine-stranded Class 6: extra-fine-stranded
Core insulation up to 6 mm² made of halogen-free PP from 10 mm² made of PVC
Core shielding of the control cores in pairs with tinned copper braid
Power cores stranded with the control pairs in layers with optimal lay lengths and stabilizing fillers Sliding
movement supporting fleece wrapping
Overall shielding made of tinned copper braid, optical coverage approx. 85%
Outer jacket made of PVC
Jacket color: orange (RAL 2003)
Properties:
Low capacitance up to and including 6 mm²
Oil-resistant PVC outer jacket
Optimal compliance with the requirements of electromagnetic compatibility (EMC) thanks to the approx. 85% dense shielding braid
These cables are manufactured according to high quality guidelines and correspond to the DESINA standard
The materials used in production are silicone and cadmium-free and free from substances that impair paint wetting
Tests:
PVC jacket flame-retardant in accordance with DIN EN 60332-1-1 to -1-3 (VDE 0482-332-1-1 to -1-3)
Use:
In these cables, the power wires are ideally combined with the control wires for the braking function and thermal protection. For EMC compatibility, i.e. immunity to interference, the cables have an additional overall shield. Production is based on the specifications of well-known servo drive and control manufacturers and in accordance with various VDE, UL and CSA standards. It is used in machine, plant and robot construction, in automation, drive, control and production technology, for example. Interesting for export-oriented machine and plant construction. EMC = Electromagnetic compatibility To optimize the EMC properties, we recommend contacting the copper braid on both sides and over a large area.
Standard lengths: 100 m, 500 m, 1000 m
Subject to technical changes.