Helukabel 34020, EAN: 4060892261558

Helukabel 34020 telecommunication cable 10x2x0.8 mm black

Cables > Underground cables > Telecommunications underground cable

Helukabel 34020 telecommunication cable 10x2x0.8 mm black

Lieske Part No. 331890
Mfg Part No 34020
EAN-Code 4060892261558
Manufacturer Helukabel
Here only 3,58 EUR
4,26 EUR incl. VAT

Further information for Helukabel 34020 telecommunication cable 10x2x0.8 mm black

General
Cable typeTelecommunications outdoor cable
Surface-mountedLayer sheath, unfilled
ConductorCu, bare, solid
Wire insulationPE (2Y)
Conductor markingblack rings
Stranding4 cores to star quad, 5 quads to basic bundle, each 5 or 10 basic bundles to main bundle
Core fillingPetrol-Jelly
Core windingPaper
Outer sheathLayer sheath (L)2Y, PE-copolymer-coated aluminium tape welded with PE sheath
Sheath colourBlack
Sheath markingContinuous telephone handset, meter marking, white
NormDIN VDE 0816
Temperature range in motion-20 °C to +50°C
Temperature range for fixed installation+70 °C
Loop resistance at 20°C (0.6 mm)130 Ohm/km
Loop resistance at 20°C (0.8 mm)73,2 Ohm/km
Operating peak voltage225 V
Test voltage core/core500 V (eff.)
Test voltage core/shield2000 V (eff.)
Insulation resistance1,5 GOhm x km
Cable attenuation at 800 Hz (0.6 mm)1,04 dB/km
Cable attenuation at 800 Hz (0.8 mm)0,78 dB/km
Characteristic impedance at 800 Hz (0.6 mm)720 Ohm
Characteristic impedance at 800 Hz (0.8 mm)520 Ohm
Minimum bending radius10x Cable Ø
Radiation resistance80 Mrad
Operating capacity at 800 Hz (0.6 mm)52 nF/km
Operating capacity at 800 Hz (0.8 mm)55 nF/km
Capacitive coupling (100%, at least two quads)800 pF/300 m
Capacitive coupling (98%, at least two quads)400 pF/300 m
Capacitive coupling (100%, quads 9-12)300 pF/300 m
Capacitive coupling (98%, quads 9-12)100 pF/300 m
CE markingcompliant with EU Low Voltage Directive 2006/95/EC
Regulation lengths100 m, 500 m, 1000 m
The Helukabel A-2Y(L)2Y Bd telecommunications outdoor cable, type 34020, is specifically designed for use in soil and cable ducts as a local subscriber cable. It serves as a connection cable in local networks and private branch exchange systems for the transmission of telephone and signal information. The cable is manufactured in accordance with DIN VDE 0816 and is intended for direct installation in soil as well as in cable conduits. It features a layered sheath consisting of a plastic-coated aluminium tape (L) and a PE outer sheath (2Y), ensuring permanent transverse and longitudinal watertightness as well as a water vapour barrier. The black PE outer sheath is UV-resistant and made of halogen-free polyethylene (PE 2Y), which increases safety in the event of fire.

Applications
This cable is intended for use in local networks and private branch exchange systems, particularly for the transmission of telephone and signal information. It is suitable for direct installation in soil as well as in cable ducts and conduits. Its use is permitted in operational facilities according to DIN VDE 0800 Part 1. Due to its special construction with continuously filled cabling voids filled with petrol jelly (F), it is designed for outdoor use, ensuring watertightness and mechanical stability even under long-term load.

Functions and Equipment in Detail
The cable consists of bare, single-strand copper conductors insulated with PE (2Y). The conductors are twisted into star quads, with each quad identified by black rings. Five quads form a basic bundle, the basic bundles are grouped into main bundles, and these are then twisted together to form the cable core. The core voids are continuously filled with petrol jelly to ensure optimal protection against moisture and mechanical stress. The core is wrapped with paper, and the outer sheath is a layered sheath (L)2Y, consisting of a double-sided PE-copolymer-coated aluminium tape welded to the PE sheath. The sheath colour is black, and the sheath marking is continuous with white print, indicating the telephone handset and metre markings.

Technology Explained Simply
The technical properties of the cable are tailored to the requirements of telecommunications and signal transmission. The loop resistance is maximum 130 Ohm/km at 20°C for conductor diameter 0.6 mm and maximum 73.2 Ohm/km for 0.8 mm. The line attenuation of the main circuits at 800 Hz is 1.04 dB/km (0.6 mm) or 0.78 dB/km (0.8 mm), enabling good signal transmission quality over long distances. The characteristic impedance is 720 Ohm (0.6 mm) or 520 Ohm (0.8 mm) at 800 Hz, ensuring stable impedance matching. The operating peak voltage is limited to a maximum of 225 V, meaning the cable is not approved for mains installation purposes. The test voltage is 500 V (rms) between conductors and 2000 V (rms) between conductor and shield. The insulation resistance is at least 1.5 GOhm x km. The operating capacitance at 800 Hz is maximum 52 nF/km (0.6 mm) or 55 nF/km (0.8 mm). Capacitive couplings are limited, with a maximum value of 800 pF/300 m (100%) and 400 pF/300 m (98%) for at least two quads. The radiation resistance is up to 80 Mrad (80x106 cJ/kg). The minimum bending radius is 10 times the cable diameter.

Compatibility and Accessories
The cable is designed for use in telecommunications and signal transmission systems and can be used in existing local networks and private branch exchange systems. It is not suitable for mains installation purposes. Use in fire- and explosion-hazardous operational facilities is only permitted with adequate protective measures. Cable types with conductor diameters of 0.6 mm and 0.8 mm are standardly available; a conductor diameter of 0.4 mm is available on request. Standard lengths are 100 m, 500 m, and 1000 m.

Installation and Mounting
The cable is intended for direct installation in soil or in cable ducts and conduits. Installation requires adherence to the minimum bending radius of 10 times the cable diameter to avoid mechanical damage. Installation must consider temperature limits: moving from -20°C to +50°C, fixed installation up to +70°C. The continuous filling of the cabling voids with petrol jelly ensures permanent moisture and water protection. The sheath marking with metre markings facilitates installation and maintenance.

Operational Advantages
The cable offers high mechanical and chemical resistance, particularly due to the layered sheath and PE insulation. The watertightness and UV resistance of the outer sheath ensure long service life in outdoor environments. The halogen-free material composition reduces fire hazard and smoke development. The low line attenuation and stable characteristic impedance ensure reliable signal transmission over long distances. The continuous filling of the cabling voids with petrol jelly prevents moisture ingress and protects the conductors against corrosion. The CE marking confirms compliance with the EC Low Voltage Directive 2006/95/EC.
This is an offer of:

Lieske Elektronik e.K.

Reutener Str. 10
79279 Vörstetten

https://industry-electronics.com
Tel. 07666/88499-0
Fax. 07666/88499-111

Diesen Artikel finden Sie unter:
industry-electronics.com/artikel/331890
qrcode für Helukabel 34020 telecommunication cable 10x2x0.8 mm black