Further information for Helukabel 33100 - HELU YY 2x2x0 6qmm Grey Bd Telecommunication Indoor Cable
J-YY Bd indoor telecommunications cable, in accordance with DIN VDE 0815
Technical specifications:
Installation cable in accordance with DIN VDE 0815
Temperature range when laying -5°C to +50°C permanently laid -30°C to +70°C
Loop resistance at 20°C max. 130 Ohm/km Peak
operating voltage max. 300 V (not for high-voltage installation purposes)
Test voltage core/core U eff. 800 V
insulation resistance min. 100 MOhm x km
operating capacitance at 800 Hz max. 100(1) nF/km
capacitive coupling at 800 Hz k(1) - max. 300 (2) pF/100 mk(9-12) - 100 (3) pF/100 m
attenuation at 800 Hz 1.48 dB/km
minimum bending radius in accordance with DIN VDE 0891 part 5 when shipping 7.5x cable Ø once. Bend without tension 2.5x cable Ø several times. Bending under tension 7.5x cable Ø
Radiation resistance up to 80x106 cJ/kg (up to 80 Mrad)
Structure:
Bare copper conductor, single-wire
Core insulation made of PVC, compound type YI1 according to DIN VDE 0207 Part 4
Core and quad identification according to DIN VDE 0815
Cores in star quad, 5 quads each in a bundle, several bundles twisted in layers
Foil wrapping
Outer jacket made of PVC, flame-retardant, compound type YM1 according to DIN VDE 0207 Part 5
Jacket color gray Properties: PVC self-extinguishing and flame-retardant according to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1 (corresponds to DIN VDE 0472 Part 804 test type B) The materials used in production are free of silicone and cadmium and free of substances that impair paint wetting
properties Notes: (1) For cables with up to 4 double wires, the values may be exceeded by 20%. (2) 20% of the values, but at least one value, may be up to 500 pF. (3) 10% of the values, but at least four values (relationships), may be up to 300 pF. Use: These installation cables are preferably used as speech cables in intercom and extension station construction in dry and damp operating locations, as well as in and under plaster, outdoors with fixed installation. Installation cables are not approved for high-voltage installation purposes or for underground installation. CE = The product conforms to the EC Low Voltage Directive 2006/95/EC. Standard lengths: 100 m, 500 m, 1000 m Subject to technical changes., J-YY Bd indoor telecommunications cable, in accordance with DIN VDE 0815 Technical data: Installation cable in accordance with DIN VDE 0815 Temperature range when laying -5°C to +50°C permanently laid -30°C to +70°C Loop resistance at 20°C max. 130 Ohm/km
Peak operating voltage max. 300 V (not for high-voltage installation purposes)
Test voltage core/core U eff. 800 V
Insulation resistance min. 100 MOhm x km
Operating capacitance at 800 Hz max. 100(1) nF/km
Capacitive coupling at 800 Hz k(1) - max. 300 (2) pF/100 mk(9-12) - 100 (3) pF/100 m
Attenuation at 800 Hz 1.48 dB/km
Minimum bending radius in accordance with DIN VDE 0891 Part 5 when shipping 7.5x cable Ø once. Bend without tension 2.5x cable Ø several times. Bending under tension 7.5x cable Ø
Radiation resistance up to 80x106 cJ/kg (up to 80 Mrad)
Structure:
Bare copper conductor, single-wire
Core insulation made of PVC, compound type YI1 according to DIN VDE 0207 Part 4
Core and quad identification according to DIN VDE 0815
Cores in star quad, 5 quads each in a bundle, several bundles twisted in layers
Foil wrapping
Outer jacket made of PVC, flame-retardant, compound type YM1 according to DIN VDE 0207 Part 5
Jacket color gray Properties: PVC self-extinguishing and flame-retardant according to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1 (corresponds to DIN VDE 0472 Part 804 test type B) The materials used in production are free of silicone and cadmium and free of substances that impair paint wetting
properties Notes: (1) For cables with up to 4 pairs, the values may be exceeded by 20%. (2) 20% of the values, but at least one value, may be up to 500 pF. (3) 10% of the values, but at least four values (relationships), may be up to 300 pF. Use: These installation cables are preferably used as speech lines in the construction of intercoms and extensions in dry and damp operating locations, as well as in and under