General
Nominal voltage450/750 V
Test voltage2500 V
Insulation resistancemin. 10 MΩ × km
Temperature range in motion-5 to +70 °C
Temperature range for fixed installation-30 to +80 °C
Radiation resistanceup to 80×10⁶ cJ/kg (80 Mrad)
Minimum bending radius4x conductor Ø (up to 8 mm), 5x conductor Ø (8–12 mm), 6x conductor Ø (>12 mm) -
StandardsDIN VDE 0285-525-2-31, DIN EN 50525-2-31, IEC 60227-3, DIN VDE 0207-363-3, DIN EN 50363-3, IEC 60227-3, DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 -
Material releaseSilicon- and cadmium-free, free of substances interfering with paint adhesion -
UtilizationInternal installation in conduits, behind plaster, in enclosed channels, internal wiring of devices, distributors, switchgear, luminaires -
Regulation lengths100 m, 500 m, 1000 m -
The H07V-K single-core cable from Helukabel, type 26826, is a PVC-insulated copper stranded conductor for use in electrical installations and industrial applications. It is used for wiring within devices, distributors, control panels, as well as in closed installation channels, conduits, under plaster, or in luminaires. The cable is rated for a nominal voltage of 450/750 V and is suitable for applications with alternating voltage up to 1000 V or direct voltage up to 750 V against earth. Direct installation on trays, troughs, or channels is not permitted.

Applications
This cable is designed for indoor use, particularly in protected installation conditions such as in wall conduits, under plaster, or in closed channels. It is suitable for internal wiring of electrical devices, control panels, and distributors. Use in luminaires is also permitted, provided the installation is protected. The cable is not intended for direct outdoor installation or for open installation on supports.

Functions and Equipment in Detail
The single-core cable consists of a bare copper stranded conductor according to DIN VDE 0295 class 5, which corresponds to a fine-stranded, flexible conductor. The insulation is made of PVC mixture type TI1, complying with standards DIN VDE 0207-363-3, DIN EN 50363-3, and IEC 60227-3. The materials used are silicone- and cadmium-free, and free from substances that could impair paint adhesion. The PVC insulation is self-extinguishing and flame-retardant according to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, and IEC 60332-1-2, corresponding to test type B according to DIN VDE 0472 part 804.

Technology Explained Simply
The cable is designed for an operating temperature of -5°C to +70°C for movable installations. For fixed installations, the temperature range is -30°C to +80°C. The test voltage is 2500 V, highlighting the electrical strength of the insulation. The insulation resistance is at least 10 MΩ × km, ensuring high insulation quality and low leakage currents. The radiation resistance is up to 80×10⁶ cJ/kg (80 Mrad), indicating suitability for environments with low radiation exposure. The minimum bending radius depends on the conductor diameter: for 8 mm conductor diameter, it is 4 times; for 8–12 mm, 5 times; and for over 12 mm, 6 times the conductor diameter.

Compatibility and Accessories
The cable is designed for use in standard installation systems and can be combined with other H05- and H07-variants, provided the standards and technical requirements are compatible. Installation is carried out in conduits, closed channels, or under plaster. Use in luminaires is only permitted with protected installation.

Installation and Mounting
Mounting is performed in closed installation systems, such as in wall conduits, under plaster, or in closed channels. The cable is not intended for direct installation on open supports such as trays or troughs. When bending, the minimum bending radius must be observed, which depends on the conductor diameter. Installation is typically carried out in lengths of 100 m, 500 m, or 1000 m, with the exact length varying according to order.

Operational Advantages
The PVC insulation provides high electrical insulation and is flame-retardant, increasing operational safety. The fine-stranded copper conductor ensures flexibility and good bending strength, especially for movable installations. The materials are free from harmful substances such as silicone and cadmium, improving compatibility with painting processes and environmental compatibility. The high radiation resistance makes the cable suitable for applications in environments with low radiation exposure.

Technical Standards and Norms
The cable complies with standards DIN VDE 0285-525-2-31, DIN EN 50525-2-31, and IEC 60227-3. The insulation complies with DIN VDE 0207-363-3, DIN EN 50363-3, and IEC 60227-3. Flame retardancy is tested according to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, and IEC 60332-1-2. The copper conductor complies with DIN VDE 0295 class 5, BS 6360 cl.5, and IEC 60228 cl.5. The nominal voltage is 450/750 V, and the test voltage is 2500 V. Insulation resistance values are at least 10 MΩ × km. Radiation resistance is up to 80 Mrad. Temperature ranges are -5°C to +70°C (movable) and -30°C to +80°C (fixed installation). The minimum bending radius varies depending on conductor diameter: 4×, 5×, or 6× the conductor diameter.