Further information for Helukabel HELU HELUFLON® FEP 6Y CU tinned HELUKA HELUFLON FEP 6Y 1x0 75 galvanized -
Technical data:
Fluoropolymer insulation FEP
Temperature range -100°C to +205°C (briefly up to +230°C)
Nominal voltage 600 V
Test voltage 2500 V
Insulation resistance min. 2 GOhm x km
Minimum bending radius moving 15x cable Ø stationary 4x cable Ø
Radiation resistance up to 1x106 cJ/kg (up to 1 Mrad)
Conductor temperature ranges Cu-bare = +130°C Cu-tinned = +180°C Cu-silver-plated = +200°C
Structure:
Cu strand bare, tinned, silver-plated
Strand structure fine-wire, in accordance with DIN VDE 0295 cl.5, BS 6360 cl.5 or IEC 60228 cl.5 Core
insulation FEP-HELUFLON®
Properties:
high insulation resistance, minimal dielectric losses, non-flammable, min. 20 kV Breakdown voltage, resistant to microcultures, does not allow fungal growth
completely ozone-resistant, absolutely weather-resistant, water absorption <0.01%
minimal water vapor permeability (approx. 0.18 mgr/cm² in 24 hours)
self-extinguishing and flame-retardant in accordance with DIN VDE 0482-332-1-2, DIN EN 60332-1-2/ IEC 60332-1 (corresponds to DIN VDE 0472 Part 804 test type B)
The materials used in production are silicone and cadmium-free and free from substances that impair paint wetting
Use:
Mainly used for installation in control cabinet construction with extreme heat generation or in ovens, brickworks, heating devices, kitchen systems, measuring devices, etc. as well as in the chemical industry, as it is absolutely flame-retardant, resistant to acids, alkalis, solvents, oil and petrol.
Standard lengths: 100 m, 1000 m
Subject to technical changes.