Technical data:

Special PVC data cable based on DIN VDE 0812
Temperature range moving -5°C to +80°C not moving -40°C to +80°C
Peak operating voltage (not for high-voltage installation purposes) 0.14 mm² 350 V = 0.25 mm² 500 V
Test voltage up to 0.25 mm² 1200 V from 0.34 mm² 2000 V
Breakdown voltage up to 0.25 mm² 2400 V from 0.34 mm² 4000 V
Operating capacitance at 800 Hz 0.14 mm² approx. 120 pF/m 0.25 mm² approx. 150 pF/m
Inductance approx. 0.65 mH/km
Characteristic impedance approx. 78 Ohm
Minimum bending radius moving 7.5x cable Ø not moving 4x Cable Ø
Radiation resistance up to 80x106 cJ/kg (up to 80 Mrad)
Structure:
Bare copper wire, from 0.5 mm² in accordance with DIN VDE 0295 class 5, fine-wire, BS 6360 cl.5, IEC 60228 cl.5
Strand structure at: 0.14 mm² approx. 18x0.1 mm 0.25 mm² approx. 14x0.15 mm 0.34 mm² = 7x0.25 mm
Core insulation made of special PVC
Core marking based on DIN 47100, without color repetition
Cores stranded in layers with optimal lay lengths
Outer jacket made of special PVC
Jacket color: gray (RAL 7001) with meter marking
Properties:
Largely oil-resistant, oil/chemical resistance
The materials used in production are silicone- and cadmium-free and free from substances that impair the wetting properties of paint
Tests:
PVC self-extinguishing and flame-retardant in accordance with DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2
Notes:
Also available with paired cores, see HELUKABEL-PAAR-TRONIC
shielded analogue type: TRONIC-CY (LiY-CY)
Use:
For flexible application with free movement without tensile stress and without forced movement in dry, damp and wet rooms, but not outdoors, wherever design or construction measures require the smallest possible external diameter of control and signal cables. This means in machine, tool and plant construction, as well as in electronics. Also in computer systems, scales, and in measurement and control technology.
Standard lengths: 100 m, 500 m, 1000 m
Subject to technical changes.
This is an offer of:

Lieske Elektronik e.K.

Reutener Str. 10
79279 Vörstetten

http://industry-electronics.com
Tel. 07666/88499-0
Fax. 07666/88499-111

Diesen Artikel finden Sie unter:
industry-electronics.com/artikel/516897
qrcode für Helukabel TRONIC 4X0,34 QMM - HELU special PVC data line 18059