Further information for Helukabel 16154 - HELU CY JB 5G16qmm Transparent Control Cable PVC
Technical data:
Special PVC hose cable based on DIN VDE 0285-525-2-51 / DIN EN 50525-2-51
Temperature range moving -15°C to +80°C stationary -40°C to +80°C
Nominal voltage up to 1.5 mm² U0/U 300/500 V from 2.5 mm² U0/U 450/750 V
Test voltage 4000 V
Breakdown voltage min. 8000 V
Operating capacity varies depending on conductor cross-section for 0.5 to 2.5 mm²: Core/core approx. 150 nF/km Core/shield approx. 270 nF/km
Coupling resistance max. 250 Ohm/km
Minimum bending radius moving 10x cable Ø stationary 5x cable Ø
Radiation resistance up to 80x106 cJ/kg (up to 80 Mrad)
Structure:
Bare copper wire, in accordance with DIN VDE 0295 cl.5, fine-stranded, BS 6360 cl.5, IEC 60228 cl.5
Core insulation made of special PVC
Core identification according to JB/OB color code
Cores stranded in layers with optimal lay lengths
Inner sheath made of PVC
Shielding braid made of tinned copper wires, coverage approx. 85%
Outer sheath made of special PVC
Sheath color: transparent with meter marking
Properties:
Largely oil-resistant, oil/chemical resistance
The materials used in production are silicone and cadmium-free and free from substances that impair paint wetting
Tests:
PVC self-extinguishing and flame-retardant in accordance with DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2
Notes:
Unshielded analogue types: JB-500 JB-750
Use:
For medium mechanical stress for flexible use with free movement without tensile stress and without forced movement in dry rooms, but not outdoors, as a control cable in control and regulation technology, in tool and machine construction, in conveyor systems and production lines, in computer systems, and as a signal cable in electronics. The high shielding density ensures interference-free transmission of signals and impulses. The applied PVC inner jacket increases the mechanical load capacity of the cable. The ideal interference-protected control cable for the above purposes. The applied clear, transparent PVC outer jacket also makes the tinned copper braid look effective. EMC = Electromagnetic Compatibility To optimize the EMC properties, we recommend contacting the copper braid on both sides and over a large area all around.
Standard lengths: 500 m, 1000 m
Subject to technical changes.