Further information for Helukabel 13373 control cable halogen-free grey
General
Degree of protection
halogen-free
Nominal voltage
300/500 V
UL/CSA rated voltage
600 V
Test voltage
3000 V
Temperature range in motion
-30 to +80 °C
Temperature range, non-operating
-40 to +80 °C
Minimum bending radius moving
10x cable Ø
Minimum bending radius not moved
4x wire Ø
Flexibility
Flex fatigue test according to DIN VDE 0473-396 / DIN EN 50396
Conductor marking
black conductors with continuous white digit marking
Wire insulation
halogen-free special polymer
Outer sheath
halogen-free special polymer
Sheath colour
grey (RAL 7001)
Flame retardancy
self-extinguishing, flame retardant
Corrosivity of fire gases
according to NF X 10-702
Halogen-free
according to DIN VDE 0482-754-1 / DIN EN 60754-1 / IEC 60754-1
Smoke density
according to DIN VDE 0482-1034-1+2 / BS 7622-1+2 / DIN EN 61034-1+2 / IEC 61034-1+2
Oil resistance
according to DIN VDE 0473-811-404 / DIN EN 60811-404
Hydrolysis resistance
According to DIN EN 61234-1
Ozone resistance
according to DIN VDE 0473-811-403 / DIN EN 60811-403
Material freedom
Silicone- and cadmium-free, free from substances interfering with paint adhesion
Utilization
Machine and plant engineering, climate technology, storage and handling technology, shipbuilding, wind turbine construction
Regulation lengths
100 m, 500 m, 1000 m
Meter marking
Recyclability
The Helukabel MEGAFLEX 500 5G 0.75 is a halogen-free, flexible control cable manufactured in accordance with DIN VDE 0285-525-3-11 and DIN EN 50525-3-11, as well as UL Style 20939 and UL Std.758. It is designed for use in industrial applications, particularly in machine and plant engineering, climate technology, storage and handling technology, shipbuilding, and wind energy. The cable is suitable for both fixed installation and flexible applications where no recurring free movement with forced guidance or tensile stress occurs, but heavy mechanical stress is expected.
Applications
This control cable is used as a measurement, control, and control cable where high requirements for mechanical strength, flexibility, and environmental resistance apply. It is particularly suitable for use in the manufacturing industry, automation technology, and the energy sector, especially in wind turbines, where the cable is used under harsh conditions and often outdoors. The high UV and weather resistance, as well as ozone resistance, make it suitable for outdoor use.
Functions and Features in Detail
The cable features a bare Cu conductor, manufactured according to DIN VDE 0295 Class 5, BS 6360 class 5, and IEC 60228 class 5, ensuring high flexibility and mechanical robustness. The conductors are insulated with a halogen-free special polymer and marked according to DIN VDE 0293 with black conductors and continuous white digit printing. The conductors are stranded in layers with optimal lay lengths, enhancing the mechanical stability and flexibility of the cable. The outer sheath is made of halogen-free special polymer in gray color (RAL 7001) with meter marking, facilitating installation and identification.
Technology Explained Simply
The rated voltage is 300/500 V, with a UL/CSA rated voltage of 600 V. The test voltage is 3000 V, ensuring high electrical strength. The cable is designed for a temperature range of -30°C to +80°C for moving installation and -40°C to +80°C for fixed installation. The minimum bending radius is 10 times the cable diameter for moving installation and 4 times for fixed installation. Flexibility is confirmed by an alternating bend test according to DIN VDE 0473-396 / DIN EN 50396, highlighting its suitability for flexible applications.
Compatibility and Accessories
The cable is available in standard lengths of 100 m, 500 m, and 1000 m. As an alternative, a 0.6/1 kV variant is available under the designation MEGAFLEX 600. A shielded analog type is available under the designation MEGAFLEX 500-C, suitable for applications requiring higher electromagnetic compatibility.
Installation and Mounting
Installation must consider the specified minimum bending radii. For moving installation, a bending radius of at least 10 times the cable diameter must be maintained; for fixed installation, at least 4 times. The cable is designed for heavy mechanical stress but is not intended for recurring free movement with forced guidance or tensile stress.
Operational Advantages
The cable features high flame protection and fire behavior properties. It is self-extinguishing and flame retardant according to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2, and CSA FT1. The fire gases are non-corrosive (according to NF X 10-702), and the cable is halogen-free (according to DIN VDE 0482-754-1, DIN EN 60754-1, IEC 60754-1). Smoke density has been tested according to DIN VDE 0482-1034-1+2, BS 7622-1+2, DIN EN 61034-1+2, and IEC 61034-1+2. The cable is resistant to oils and fats, hydrolysis-resistant, ozone-resistant, abrasion- and wear-resistant, and recyclable. The materials used are silicone- and cadmium-free and free of substances that interfere with lacquer adhesion, enhancing processability and environmental compatibility.