Further information for Helukabel HELU control cable H05VV5 3G2 5mm² - H05VV5-F (NYSLYÖ-JZ)
Technical data:
Special PVC control cable with oil-resistant outer sheath in accordance with DIN VDE 0285-525-2-51 / DIN EN 50525-2-51 and IEC 60227/75
Temperature range moving -5°C to +70°C fixed -40°C to +70°C
Nominal voltage U0/U 300/500 V
Test voltage 2 kV, 5 minutes
Breakdown voltage min. 4000 V
Insulation resistance min. 20 MOhm x km
Minimum bending radius moving 7.5x cable Ø fixed 4x cable Ø
Radiation resistance up to 80x106 cJ/kg (up to 80 Mrad)
Structure:
Bare copper wire, in accordance with DIN VDE 0295 cl.5, fine-wire, BS 6360 cl.5, IEC 60228 cl.5
Core insulation made of special PVC
Core identification in accordance with DIN VDE 0293 black cores with continuous white numbering
Cores twisted in layers with optimal lay lengths
Outer jacket made of special PVC
Jacket color: gray (RAL 7001) with meter marking
Properties:
The materials used in production are free from silicone and cadmium and free from substances that impair paint wetting
Tests:
PVC self-extinguishing and flame-retardant in accordance with DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1
Oil-resistant in accordance with DIN EN 60811-404
Notes:
shielded analogue type: H05VVC4V5-K (NYSLYCYÖ-JZ)
Use:
For medium mechanical stress for flexible application with free movement without tensile stress and without forced movement in dry, damp and wet rooms, but not outdoors as a control and connection cable in machine and machine tool construction, on production and assembly lines, Conveyor systems and production lines. Various chemical compounds cannot harm the cable. It is also preferred as a damp room cable for operating machines in breweries, bottling plants and washing systems. The cables can be moved after installation, provided that the cables are not mechanically overloaded during the movement.
Standard lengths: 100 m, 500 m, 1000 m.
Technical changes reserved.