Helukabel 13033, EAN: 4060892012181

Helukabel 13033 hose cable H05VV5-F 25G1,0 mm² grey

Cables > Installation systems and industrial management > Hose H03/05VV-F

Helukabel 13033 hose cable H05VV5-F 25G1,0 mm² grey

Lieske Part No. 329418
Mfg Part No 13033
EAN-Code 4060892012181
Manufacturer Helukabel
Here only 8,24 EUR
9,81 EUR incl. VAT

Further information for Helukabel 13033 hose cable H05VV5-F 25G1,0 mm² grey

General
Degree of protectionoil-resistant outer sheath made of special PVC
Operating voltage300/500 V
Temperature range in motion-5 °C up to +70°C
Temperature range, non-operating-40 °C up to +70°C
Minimum bending radius moving7,5x cable Ø
Minimum bending radius not moved4x cable Ø
Radiation resistance80x106 cJ/kg
Insulation resistance20 MOhm x km
Test voltage2 kV
Test duration5 minutes
Dielectric strength4000 V
Conductor markingblack conductors with continuous white digit marking
Sheath colourGrey RAL 7001
MaterialsSilicon- and cadmium-free, free of substances interfering with paint adhesion
TestsSelf-extinguishing and flame retardant according to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1; oil resistant according to DIN EN 60811-404
Regulation lengths500 m, 1000 m
StandardsDIN VDE 0285-525-2-51, DIN EN 50525-2-51, IEC 60227/75
Conductor constructionBare Cu stranded wire, DIN VDE 0295 class 5, fine-stranded
Wire insulationspecial PVC
Outer sheathspecial PVC
Shielded analog typeH05VVC4V5-K (NYSLYCYÖ-JZ)
Utilizationmachine and machine tool construction, conveyor and assembly lines, material handling systems, production lines, breweries, filling plants, washing plants
Operating environmentDry, damp and wet rooms, not for outdoor use
Tensile stressnot provided
Forced motion guidancenot provided
Chemical resistanceresistant to oils and various chemical compounds
Technical changesReserved
Meter markingYes
The Helukabel cable type 13033 is a special PVC control cable with oil-resistant outer sheath, designed for flexible applications in industrial environments. It complies with standards DIN VDE 0285-525-2-51, DIN EN 50525-2-51 and IEC 60227/75 and is suitable for medium mechanical stress with free movement without tensile load. The cable is used in dry, damp and wet rooms, but not outdoors. It is particularly suitable for use in machine and tool machine construction, conveyor and assembly lines, material handling systems and production lines. Due to its chemical resistance, it is also used in breweries, filling plants and washing facilities.

Applications

The cable is designed for flexible applications where the cable may be moved after installation, provided no mechanical overload occurs. It is not intended for forced movement guidance or under tensile stress. The operating environments include dry, damp and wet rooms, with the cable not intended for outdoor use. The materials are free of silicone, cadmium and substances that could impair paint adhesion, making it particularly suitable for applications in manufacturing and machine building.

Functions and equipment in detail

The cable consists of bare Cu conductors according to DIN VDE 0295 class 5, which are fine-stranded and comply with standards BS 6360 class 5 and IEC 60228 class 5. The conductors are insulated with special PVC and marked according to DIN VDE 0293 with black conductors and continuous white digit printing. The conductors are stranded in layers with optimal lay lengths, ensuring even distribution of mechanical stress. The outer sheath is also made of special PVC and is grey in colour (RAL 7001), with an integrated meter marking to facilitate length measurement.

Technology explained simply

The rated voltage is 300/500 V, qualifying the cable for typical control and connection applications in industry. The test voltage of 2 kV over 5 minutes and the breakdown voltage of at least 4000 V ensure high electrical strength. The insulation resistance is at least 20 MOhm x km, ensuring reliable insulation even over long cable lengths. The radiation resistance up to 80x106 cJ/kg (80 Mrad) makes the cable suitable for applications in environments with increased radiation exposure. The temperature resistance is between -5°C and +70°C for moving cable, and between -40°C and +70°C for stationary cable. The minimum bending radius is 7.5 times the cable Ø for moving cable and 4 times the cable Ø for stationary cable.

Compatibility and accessories

The cable is compatible with systems requiring a control and connection cable with medium mechanical stress. As a shielded analog type, the H05VVC4V5-K (NYSLYCYÖ-JZ) is mentioned, suitable for applications with higher requirements for electromagnetic compatibility. The cable is available in standard lengths of 500 m and 1000 m, with technical changes reserved.

Installation and mounting

Installation must consider mechanical load capacity. The cable may be moved after installation, provided no mechanical overload occurs. Minimum bending radii must be observed to ensure cable lifespan. The meter marking facilitates length measurement and positioning during installation.

Operational advantages

The cable is characterised by its high chemical resistance, particularly against oils and various chemical compounds. The self-extinguishing and flame-retardant properties of the PVC sheath according to DIN VDE 0482-332-1-2, DIN EN 60332-1-2 and IEC 60332-1 increase operational safety. The oil-resistant surface ensures long service life even in dirty environments. The material release of silicone and cadmium, as well as the avoidance of paint-adhesion interfering substances, makes the cable suitable for demanding industrial applications.

Protection rating

The cable is not specified with an IP protection rating, however, the outer sheath is made of oil-resistant special PVC, ensuring high resistance against mechanical and chemical influences. Use in wet rooms is possible, but not intended for outdoor use.

Operating voltage

The rated voltage of 300/500 V is suitable for typical control and connection applications in industry. The test voltage of 2 kV over 5 minutes and the breakdown voltage of at least 4000 V ensure electrical strength.

Temperature range

The cable can be operated in the temperature range of -5°C to +70°C for moving applications and -40°C to +70°C for stationary applications.

Minimum bending radius

The minimum bending radius is 7.5 times the cable Ø for moving cable and 4 times the cable Ø for stationary cable.

Radiation resistance

The cable is radiation resistant up to 80x106 cJ/kg (80 Mrad), making it suitable for applications in environments with increased radiation exposure.

Insulation resistance

The insulation resistance is at least 20 MOhm x km, ensuring reliable insulation even over long cable lengths.

Testing

The cable meets the requirements for self-extinguishing and flame-retardant PVC according to DIN VDE 0482-332-1-2, DIN EN 60332-1-2 and IEC 60332-1. Oil resistance is tested according to DIN EN 60811-404.

Conductor identification

The conductors are marked according to DIN VDE 0293 with black conductors and continuous white digit printing, enabling clear identification.

Sheath colour

The outer sheath is grey (RAL 7001) and features a meter marking to facilitate length measurement.

Materials

The materials used are free of silicone and cadmium and free of substances that impair paint adhesion, making the cable suitable for demanding industrial applications.

Standard lengths

The cable is supplied in standard lengths of 500 m and 1000 m.
This is an offer of:

Lieske Elektronik e.K.

Reutener Str. 10
79279 Vörstetten

https://industry-electronics.com
Tel. 07666/88499-0
Fax. 07666/88499-111

Diesen Artikel finden Sie unter:
industry-electronics.com/artikel/329418
qrcode für Helukabel 13033 hose cable H05VV5-F 25G1,0 mm² grey