Further information for Helukabel 10953
Technical data:
Special PVC hose cable based on DIN VDE 0285-525-2-51 / DIN EN 50525-2-51
Temperature range moving -10°C to +80°C fixed -40°C to +80°C
Nominal voltage U0/U 300/500 V
Test voltage core/core 4000 V core/shield 2000 V
Breakdown voltage min. 8000 V
Insulation resistance min. 20 MOhm x km
Coupling resistance max. 250 Ohm/km
Minimum bending radius moving 10x cable Ø fixed 5x cable Ø
Radiation resistance up to 80x106 cJ/kg (up to 80 Mrad)
Structure:
Bare copper wire, in accordance with DIN VDE 0295 cl.5, fine-wire, BS 6360 cl.5, IEC 60228 cl.5
Core insulation made of special PVC
Core identification according to DIN VDE 0293 Black cores with continuous white numbering
Cores stranded in layers with optimal lay lengths
Foil wrapping Shielding
braid made of tinned copper wires, coverage approx. 85%
Outer jacket made of special PVC
Jacket color: black (RAL 9005) with meter marking
Properties:
Largely oil-resistant, oil/chemical resistance
The materials used in production are silicone and cadmium-free and free from substances that impair paint wetting
UV-resistant
Tests:
PVC self-extinguishing and flame-retardant according to DIN VDE 0482-332-1-2 / DIN EN 60332-1-2 / IEC 60332-1-2
Notes:
Unshielded analogue type: JZ-500 black
Use:
For medium mechanical stress for flexible application with free movement without tensile stress and without forced movement in dry, damp and wet rooms, and outdoors. Must not be laid directly in the ground or water. As a shielded measuring, monitoring and control cable in mechanical and plant engineering, on machine tools, production lines, assembly lines and conveyor belts, among other things. EMC = Electromagnetic Compatibility To optimize the EMC properties, we recommend a large-area, all-round contact on both sides of the copper braid.
Standard lengths: 100 m, 500 m, 1000 m
Subject to technical changes.