Further information for Helukabel 10692 control cable 4G 2,5 mm² black
General
Nominal voltage
300/500 V
Test voltage
4000 V
Dielectric strength
8000 V
Insulation resistance
20 MΩ·km
Temperature range in motion
-15 to +80 °C
Temperature range, non-operating
-40 to +80 °C
Minimum bending radius moving
7.5x cable Ø
Minimum bending radius not moved
4x wire Ø
Copper stranded wire
DIN VDE 0295 Class 5
Wire insulation
special PVC
Conductor marking
orange with black digit print
Outer sheath
special PVC
Sheath colour
orange (RAL 2003)
Self-extinguishing and flame retardant
according to DIN VDE 0482-332-1-2 / DIN EN 60332-1-2 / IEC 60332-1-2
Utilization
locking technology, medium mechanical stress, indoor use
Regulation lengths
50 m, 100 m, 500 m, 1000 m
Meter marking
Oil- and chemical-resistant
Silicone- and cadmium-free
Free of substances impairing paint adhesion
The Helukabel control cable type 10692 is a flexible special PVC cable specifically designed for use in interlock technology. It complies with the requirements of standards DIN VDE 0285-525-2-51 and DIN EN 50525-2-51 and is designed for medium mechanical stress. The cable is suitable for flexible applications with free movement without tensile stress and without forced movement guidance, particularly in dry, damp, and wet rooms. Outdoor use is not intended. According to DIN EN 60204-1 or VDE 0113-1, it is recommended to mark insulated conductors of interlock circuits that remain energized when the main switch is turned off in orange — a marking achieved with this cable through the orange (RAL 2003) outer sheath color and continuous black digit marking on the conductors.
Applications
Control cable 10692 is used in industrial plants where safety-relevant interlock systems play a role, for example in machine construction, conveyor technology, or plant engineering. The cable is suitable for use in environments with medium mechanical load, where it is moved but not pulled. It is intended for indoor use, regardless of humidity, as long as there is no direct sunlight or weather influences outdoors. The cable is used in circuits classified as interlock circuits according to the mentioned standards.
Functions and Equipment in Detail
The cable consists of bare copper strands according to DIN VDE 0295 class 5, ensuring a fine-stranded, flexible structure. The conductors are insulated with special PVC and stranded in layers, ensuring optimal lay lengths to achieve even distribution of mechanical stress. Conductor identification follows DIN VDE 0293 with orange-colored conductors and a continuous black digit print, enabling identification of individual conductors. The outer sheath is also made of special PVC and is orange (RAL 2003), with an integrated meter marking to visually control length during installation.
Technology Explained Simply
The rated voltage is 300/500 V, indicating the maximum voltage the cable can safely transmit. The test voltage of 4000 V and the breakdown voltage of at least 8000 V ensure electrical safety and insulation quality. The insulation resistance of at least 20 MΩ·km ensures high electrical insulation and minimizes leakage currents. Radiation resistance up to 80 Mrad (80x10⁶ cJ/kg) makes the cable suitable for applications where it may be exposed to ionizing radiation, for example in medical technology or nuclear technology. Temperature resistance ranges from -15 °C to +80 °C for moving applications and from -40 °C to +80 °C for stationary applications. The minimum bending radius is 7.5 times the cable diameter for moving use and 4 times for stationary use, ensuring flexibility and longevity during bending.
Compatibility and Accessories
The cable is designed for use in interlock systems executed according to DIN EN 60204-1 or VDE 0113-1. The orange coloring of the conductors and sheath corresponds to recommendations for interlock circuits that remain energized even after the main switch is turned off. The materials used are silicone- and cadmium-free and free from substances that could impair paint adhesion, facilitating processing in painting or coating processes. The PVC insulation is self-extinguishing and flame-retardant according to DIN VDE 0482-332-1-2 / DIN EN 60332-1-2 / IEC 60332-1-2, reducing fire load in case of a short circuit.
Installation and Mounting
Installation takes place indoors, with the cable used for free movement without tensile stress. The meter marking facilitates length control during installation. The flexible construction with fine-stranded copper strands allows easy bending and installation, while the minimum bending radius must be observed to ensure service life. The cable is not intended for outdoor use, as it is not protected against UV radiation or weather influences.
Operational Advantages
Control cable 10692 offers high mechanical and thermal load capacity, suitable for use in industrial environments. The oil- and chemical-resistant materials ensure long service life, even in environments with aggressive media. The flame-retardant PVC insulation increases operational safety. Clear marking of conductors and sheath simplifies installation and maintenance. Radiation resistance extends the application range to special applications where ionizing radiation occurs. The cable is available in standard lengths of 50 m, 100 m, 500 m, and 1000 m, providing flexibility for planning and installation.