The Hager access cable assembly type Y87H is a 4-pole connection cable assembly for use in meter enclosures and distributors. It serves as a connecting element between the power supply and the metering area, with conductor cross-sections for all poles designed for 10 mm². The designation univers Z indicates universal applicability in various metering systems, particularly in systems according to DIN VDE 0603/1 and DIN 43 870. The cable assembly construction enables a secure and structured routing of the conductors, with connections for phases L1, L2, L3 and the neutral conductor N having lengths of 500 mm (L1, L2, L3) and 675 mm (N). The designation H/H indicates a horizontal arrangement of the connections, allowing cables to be introduced from the top and bottom into the enclosure.
Access cable assembly
Article Y87H is specifically designed for use in meter and distributor units, where a reliable and standard-compliant connection between the power supply and the metering area is required. The 4-pole configuration meets standard requirements for three-phase AC supplies, including the neutral conductor. The conductor cross-sections of 10 mm² comply with requirements for rated currents up to 63 A in typical residential supply according to DIN 18015-1, making it suitable for typical residential and small consumer installations. The lengths of the individual connection conductors are dimensioned to allow flexible installation within the enclosure without requiring additional extensions.
Functions and equipment in detail
The cable assembly is designed for use in mounting kits consisting of a single row. The connection points are designed to ensure a secure and mechanically stable connection. The cables are pre-fabricated and supplied with the required lengths, reducing installation time. The designation H/H describes the horizontal arrangement of the connections, allowing cables to be introduced from the top and bottom into the enclosure. The design as an access cable assembly enables a direct connection to the metering area, with the conductors already cut to the required lengths.
Technology explained clearly
The 4-pole construction of the cable assembly covers the three phases (L1, L2, L3) and the neutral conductor (N), which is required for supplying three-phase consumers. The conductor cross-sections of 10 mm² are designed for rated currents up to 63 A, meeting requirements for residential and small consumer installations. The lengths of the individual conductors (500 mm for L1, L2, L3 and 675 mm for N) allow flexible positioning within the meter enclosure. The horizontal arrangement (H/H) simplifies installation and access to the connection points. The cables are designed for a secure and durable connection, with materials meeting the requirements of VDE-AR-N 4100:2019-04.
Compatibility and accessories
The access cable assembly Y87H is specifically designed for use in meter enclosures and distributors executed according to DIN VDE 0603/1 and DIN 43 870. It is compatible with mounting kits consisting of a single row. As suitable accessories, article Y87E access cable assembly universZ 10 mm² 4-pole is offered, which serves a similar function. Combination with other components such as meter boxes or distributors is carried out according to the technical specifications of the respective standards. Use in systems with multiple meter positions is possible, with the exact number of positions varying according to the enclosure configuration.
Installation and mounting
Mounting of the cable assembly takes place within the meter enclosure, with cables introduced from the top and bottom. The horizontal arrangement (H/H) enables simple and clear routing. The pre-fabricated lengths of the conductors (500 mm for L1, L2, L3 and 675 mm for N) facilitate installation, as no additional cutting work is required. The connection is made directly to the meter connection points, with standards VDE-AR-N 4100:2019-04 and DIN VDE 0100-443/-534 to be observed. Mounting is part of the overall installation of the meter enclosure and requires compliance with technical specifications.
Operational advantages
The use of the Hager access cable assembly Y87H provides a structured and secure connection between the power supply and the metering area. The pre-fabricated cables with the required lengths reduce installation time and minimize error sources. The 4-pole configuration meets standard requirements for three-phase supplies, with conductor cross-sections of 10 mm² complying with requirements for residential and small consumer installations. The horizontal arrangement (H/H) enables flexible and clear installation within the enclosure. Compatibility with standards such as DIN VDE 0603/1 and VDE-AR-N 4100:2019-04 ensures safe and reliable operation.
Sustainability
Article Y87H complies with the requirements of the REACh-SVHC regulation and is RoHS-compliant, ensuring the use of non-hazardous materials and environmental compatibility. The materials are selected to meet the requirements of electrical engineering and ensure a long service life. The construction takes sustainability requirements into account without impairing functionality or safety.
Compatibility
The article is designed for mounting kits with a single row and can be used in meter enclosures according to DIN VDE 0603/1 and DIN 43 870. Suitable accessories include article Y87E access cable assembly universZ 10 mm² 4-pole.
Sustainability
The article is REACh-SVHC free and RoHS-compliant, ensuring the use of non-hazardous materials and environmental compatibility.
Compatibility
The article is designed for mounting kits with a single row and can be used in meter enclosures according to DIN VDE 0603/1 and DIN 43 870. Suitable accessories include article Y87E access cable assembly universZ 10 mm² 4-pole.
Sustainability
The article is REACh-SVHC free and RoHS-compliant, ensuring the use of non-hazardous materials and environmental compatibility.