Hager TYMS646T, EAN: 3250610050125

HAGER TYMS646T - Heating actuator 6f KNX Secure 24/230V

Software > Data Security > Licenses

HAGER TYMS646T - Heating actuator 6f KNX Secure 24/230V

Lieske Part No. 679635
Mfg Part No TYMS646T
EAN-Code 3250610050125
Manufacturer Hager
Here only 175,46 EUR
208,80 EUR incl. VAT

Further information for HAGER TYMS646T - Heating actuator 6f KNX Secure 24/230V

General
Other bus systemsNone
Mounting methodDRA (DIN-rail adapter)
Width in number of modular spacings4
Max. switching current (resistive load)0.16 A
Number of outputs6
Max. output current0.16 A
Switching voltage230 V
Degree of protection (IP)IP20
Number of digital inputs0
Bus system KNXyes
Bus system KNX radiono
Bus system radio frequentno
Bus system LONno
Bus system Powernetno
Radio frequent bidirectionalno
Bus connection includedyes
Bus module detachableno
Correcting variable consistentyes
Correcting variable switchingyes
Valve protection functionyes
Manual switchyes
Heating actuator 6-way KNX Secure for 24/230V actuators, Triac. Heating actuator (REG) KNX Secure with electronic outputs (Triac) for silent control of electrothermal actuators for heating systems or cooling ceilings.
Modular device with integrated bus coupler, bus connection via KNX connection terminal, slide switch auto/manual, 6 manual buttons for open/close per actuator channel with status LED (default, short circuit, overload), programming button with integrated LED, labeling field and screw terminals for input and output voltages.
Functions: Output voltage for compatible valves 230 V AC or 24 V AC, temperature controller for heating and cooling, with 12 temperature controllers for controlling up to 12 independent zones, on/off or PWM control. Manual operation via slide switch of the channel with 0% - 50% - 100%. Diagnostic function via output with multi-colored LED, time/date programmable valve protection/pump seizure protection and forced position. Different values for summer/winter operation. 2 x logic block. Parameterizable setpoints for normal, forced or emergency operation. Cyclic monitoring/detection of the input signals from thermostats (monitoring time approx. 45 min). If the thermostat is defective, the triac output is set to emergency operation.
Note: The device can be programmed using the ETS (from version 5). Actuators with the same operating voltage must be connected to all actuator channels. Observe the installation instructions for heating system/actuator manufacturers.
This is an offer of:

Lieske Elektronik e.K.

Reutener Str. 10
79279 Vörstetten

https://industry-electronics.com
Tel. 07666/88499-0
Fax. 07666/88499-111

Diesen Artikel finden Sie unter:
industry-electronics.com/artikel/679635
qrcode für HAGER TYMS646T - Heating actuator 6f KNX Secure 24/230V