Further information for Hager MBN132 Circuit Breaker 1P 32A
General
Release characteristic
B
Number of poles (total)
1
Number of protected poles
1
Rated current
32 A
Rated voltage
400
Rated insulation voltage Ui
500 V
Rated impulse withstand voltage Uimp
4 kV
Rated short-circuit breaking capacity Icn EN 60898 at 230 V
6 kA
Rated short-circuit breaking capacity Icu IEC 60947-2 at 230 V
10 kA
Voltage type
AC
Frequency
60
Current limiting class
3
Over voltage category
3
Pollution degree
2
Width in number of modular spacings
1
Built-in depth
70 mm
Degree of protection (IP)
IP20
Ambient temperature during operating
70
Connectable conductor cross section multi-wired
25
Connectable conductor cross section solid-core
35
Power loss
4.40 W
Concurrently switching N-neutral
Additional equipment possible
Explosion-proof
Flush-mounted installation
The Hager circuit breaker MBN132 is a 1-pole switch with B characteristic and a rated current of 32 A. It is designed for use in electrical installations in residential and commercial buildings and provides protection against overload and short circuit. The version with 6 kA breaking capacity (Icn according to IEC 60898-1) ensures safe disconnection in case of high current surges. The switch is designed for a rated voltage of 400 V AC and features a rated insulation voltage of 500 V as well as a rated impulse voltage withstand of 4 kV. The energy limitation class 3 and the overvoltage category 3 make it suitable for applications in medium overvoltage areas. The operating temperature range is from -25 °C to 70 °C, with the rated current being exactly 32 A at 30 °C. At higher temperatures, the rated current decreases gradually, reaching 28 A at 70 °C.
Applications
The MBN132 is intended for use in electrical distributions in residential and commercial buildings. It is suitable for protecting circuits loaded with a rated current of up to 32 A. The 1-module mounting width enables compact installation in standard distribution boxes. The protection class IP20 protects against contact with fingers and larger solid objects, but is not suitable for outdoor use or in damp environments. Installation is done flush-mounted, with a 360° mounting option available.
Functions and Equipment in Detail
The switch features a B characteristic, enabling selective disconnection in case of overload. The B tripping characteristic reacts to a current of approximately 3 to 5 times the rated current within seconds, which is typical for consumers with low inrush current. The connection terminals are designed as screw terminals, with the upper terminal being of the biconnect type for modular devices. The connection cross-sections range from 1 to 35 mm² for solid conductors and from 1 to 25 mm² for stranded conductors. The nominal torque is 2.80 Nm for both terminals. The power loss at rated current is 4.40 W.
Technology Explained Simply
The B characteristic ensures that the switch does not unnecessarily trip under normal load, but only reacts in case of sustained overload or short circuit. The energy limitation class 3 means that the switch limits the energy of a short circuit, reducing the thermal stress on the conductors. The rated switching capacity Icn (6 kA) and Icu (10 kA according to IEC 60947-2) define the maximum current the switch can safely interrupt. The rated voltage of 400 V AC covers typical low-voltage installations. The insulation strength of 500 V Ui and the impulse voltage withstand of 4 kV ensure safe electrical isolation.
Compatibility and Accessories
The MBN132 is designed for mounting in standard distribution boxes with modular construction. It is compatible with phase bar systems such as KDN363B or KDN363A, designed for 3-pole connections. Additionally, cable bridges such as K67C or K67H can be used to connect conductors. Signal contacts such as MZ202 or auxiliary contacts such as MZ201 can be used for additional control or signaling functions. Locking devices such as MZN175 or spacers such as LZ060 support installation and maintenance. End caps such as KZN023 protect the ends of the phase bar.
Mounting and Installation
Installation is flush-mounted in distribution boxes. The 1-module width allows flexible placement next to other devices. The screw terminals require a torque of 2.80 Nm. The 360° mounting option provides flexibility during installation. The mounting depth is 70 mm, with a grid spacing of 60 mm. The terminals are designed for both flexible and rigid conductors, with maximum cross-sections of 25 mm² (stranded) and 35 mm² (solid).
Advantages in Operation
The MBN132 provides reliable protection with clearly defined tripping characteristics. The compact design and modular mounting facilitate integration into existing systems. The power loss of 4.40 W is on the lower end compared to other switches, resulting in reduced heat generation. Certification according to DIN VDE 0641 Part 11/08/92 and RoHS compliance ensure adherence to applicable standards. The protection class IP20 provides sufficient protection against contact, assuming indoor use. The combinability with various accessories expands the application possibilities in electrical installations.