Hager CDS440D, EAN: 3250611610861

Hager CDS440D RCD 4-pole

Installation > Modular devices / equipment installation > RCD

Hager CDS440D RCD 4-pole

Lieske Part No. 108447
Mfg Part No CDS440D
EAN-Code 3250611610861
Manufacturer Hager
Here only 132,34 EUR
157,48 EUR incl. VAT

Further information for Hager CDS440D RCD 4-pole

General
Number of poles4
Rated voltage400 V
Rated current40 A
Rated fault current0.03 A
Rated insulation voltage Ui500 V
Rated impulse withstand voltage Uimp4 kV
Mounting methodDIN rail
Leakage current typeA
Short-circuit breaking capacity (Icw)6 kA
Surge current capacity0.25 kA
Frequency50 Hz
Degree of protection (IP)IP20
Width in number of modular spacings4
Built-in depth70 mm
Ambient temperature during operating40 °C
Pollution degree2
Connectable conductor cross section multi-wired16 mm²
Connectable conductor cross section solid-core25 mm²
ColourGrey
Power loss6.50 W
RAL-number (akin)7005
Voltage typeAC
Selective protectionno
Short-time delayed trippingno
Additional equipment possibleyes
With interlocking deviceyes
Explosion-proofno
The Hager residual current circuit breaker type CDS440D is a 4-pole residual current circuit breaker (RCCB) for use in electrical installations. It provides protection against dangerous earth fault currents and is designed for mounting on a DIN rail. With a rated voltage of 400 V and a rated current of 40 A, it is suitable for applications in residential and commercial buildings where reliable disconnection in the event of earth faults is required. The breaker detects fault currents from 30 mA (0.03 A) and is designed as Type A, meaning it also detects pulsating and surging currents, such as those occurring in devices with DC components. The short-circuit withstand capability is 6 kA, ensuring high safety in the event of short-circuit incidents. The rated insulation voltage is 500 V, and the rated impulse withstand voltage is 4 kV, enabling use in electrical systems with high voltage surges.

Applications

The RCCB CDS440D is intended for use in indoor electrical distributions, particularly in residential and commercial buildings. It protects people and installations against dangerous fault currents and is suitable for AC systems at a frequency of 50 Hz. The maximum operating temperature is 40 °C, and the breaker can be used at altitudes up to 2000 m above sea level. The protection rating IP20 ensures protection against contact with solid objects larger than 12.5 mm and against vertically falling water droplets, although it is not suitable for outdoor use or in damp rooms. Pollution degree 2 indicates that the breaker is suitable for environments with low pollution, such as those found in normal indoor spaces.

Functions and Equipment in Detail

The breaker features QuickConnect technology, enabling fast and secure connection of conductors without requiring additional tools. The connection cross-sections are designed for single-core conductors up to 25 mm² and multi-core conductors up to 16 mm². The terminals are aligned to facilitate modular mounting. The power loss is 6.50 W, limiting thermal load during operation. The installation depth is 70 mm, and the breaker occupies 4 module units on the DIN rail. The locking device enables secure disconnection and prevents accidental re-energization.

Technology Explained Simply

The residual current circuit breaker monitors current flow in the circuit and automatically disconnects when a difference between incoming and outgoing current is detected — an indication of a fault current caused by insulation damage or a short circuit. The Type A design also detects pulsating fault currents, which occur in devices with electronic circuits (e.g., LED lighting, frequency converters). The short-circuit withstand capability of 6 kA means the breaker safely disconnects even under high short-circuit currents without damage. The rated insulation voltage of 500 V and impulse voltage withstand of 4 kV ensure reliable operation even under transient voltage surges, such as those caused by lightning strikes or switching operations.

Compatibility and Accessories

The breaker is designed for mounting on a DIN rail and can be combined with various accessories to extend functionality. These include, for example, the cable bridge NYAF 10 mm² (available in various lengths and versions), the phase bar 4P fork for power distribution, and locking devices for additional security. Additional devices can be added to meet specific requirements such as remote control or status indication. The QuickConnect technology enables easy integration into existing installations.

Mounting and Installation

Mounting is done on a DIN rail, with terminals designed for connecting conductors. The nominal torques for the upper and lower terminals are each 2.80 Nm. The installation depth of 70 mm must be considered during planning of the distribution board. The dimensions of the device are 83 mm (height), 70 mm (width), and 70 mm (depth). The grey colour (similar to RAL 7005) matches standard distribution boards. The device lifespan is 4000 mechanical and 2000 electrical switching operations, ensuring high operational reliability over a long period.

Operational Advantages

The breaker provides reliable disconnection at fault currents from 30 mA, ensuring protection for people and installations. The QuickConnect technology reduces installation time and minimizes wiring errors. The compatibility with additional devices allows flexible adaptation to specific requirements. The IP20 protection rating and pollution degree 2 make it suitable for use in normal indoor environments without requiring special protective measures. The rated voltage of 400 V and short-circuit withstand capability of 6 kA ensure safe operation in typical electrical systems. The locking device provides additional safety during maintenance and servicing.