General
Degree of protectionIP67
Sealing range5-10 mm
ThreadM16
Filament test960 °C
Add-on typeFor pre-punched holes
Tightening torque for cap nut3 Nm
Tightening torque for locknut3 Nm
Tension reliefType A
Suitable for wall thicknessup to 3 mm
Maximum ambient temperature70 °C
Minimum ambient temperature-25 °C
Relative humidity≤ 50 % at 40 °C, ≤ 100 % at 25 °C
MaterialPolyamide
Flame retardancy classUL 94 V-0
Temperature resistance-30 to +100 °C
Maximum diameter of through hole16,3 mm
Thread length8 mm
Wrench size for fitting20 mm
Wrench size for locknut22 mm
Corner dimension for fitting22 mm
Corner dimension for locknut24,7 mm
Compliance with standardsDIN EN 62444
CertificateDNV GL TAE000041H
Cable clampYes
Halogen freeYes
Silicone-freeYes
WeatherproofYes
The AKM 16 cable gland from Gustav Hensel is a waterproof and dust-protected component for installation in outdoor areas or humid environments. It is specifically designed for mounting on pre-drilled holes with an M16 thread and serves for the secure and tight introduction of cables with a diameter of 5 to 10 mm. The protection class IP67 ensures that the cable gland is dust-tight and can be used temporarily up to a depth of 1 meter for 30 minutes under water without water entering the protected device. This makes it suitable for locations exposed to high humidity or occasional water exposure.

Applications

The cable gland is intended for unprotected installations, i.e., for use outdoors or in industrial environments with high requirements for environmental resistance. It is designed for a maximum ambient temperature of 70 °C and a minimum temperature of -25 °C. The relative humidity may reach up to 50 % at 40 °C and up to 100 % at 25 °C. The material properties, particularly weather resistance, ensure that the gland remains stable even under UV radiation, ice, seawater, and corrosive conditions.

Functions and Equipment in Detail

The AKM 16 features an integrated cable clamp that ensures secure strain relief and protects the cable from mechanical stress. The strain relief is of type A, which involves mechanical fixation of the cable via a clamp. Mounting is done using a lock nut and a counter nut, with a tightening torque of 3 Nm for both. The maximum wall thickness for which the gland is suitable is 3 mm. The glow wire test according to IEC 60695-2-11 with a value of 960 °C demonstrates the high heat resistance of the material, which is made of polyamide.

Technology Explained Simply

The cable gland is made of polyamide material, which is flame-retardant, self-extinguishing, halogen-free, and silicone-free. The flame resistance class UL 94 V-0 confirms the low fire hazard. The temperature resistance ranges from -30 °C to +100 °C, enabling broad application. Sealing is achieved via an elastic ring that adapts to the cable diameter, creating a tight connection. The maximum bore diameter is 16.3 mm, and the thread is M16 x 1.5. The wrench size for the gland is 20 mm, and for the counter nut, it is 22 mm.

Compatibility and Accessories

The cable gland is specifically designed for pre-drilled holes with an M16 thread. It is suitable for cables with a diameter of 5 to 10 mm. Mounting is done by screwing into the pre-drilled hole, with the counter nut providing secure fastening. Compliance with standards is according to DIN EN 62444, confirming adherence to European safety standards. Certification by DNV GL TAE000041H underscores the product’s quality and reliability.

Mounting and Installation

Mounting is done by inserting the cable gland into the pre-drilled hole with M16 thread. The cable is passed through the gland, the cable clamp is tightened, and the lock nut and counter nut are tightened with a torque of 3 Nm. The maximum wall thickness is 3 mm, allowing installation in thin walls or panels. The material properties permit mounting in environments with high mechanical and thermal loads.

Advantages in Operation

The AKM 16 offers high mechanical and chemical resistance. The protection class IP67 protects against dust and temporary submersion. The integrated strain relief prevents cable pull-out. The use of polyamide ensures high weather resistance, including UV and corrosion protection. The halogen-free and silicone-free composition reduces fire hazard and protects sensitive electronic components from harmful emissions in case of fire. The maximum ambient temperature of 70 °C and minimum temperature of -25 °C allow use in a wide range of climatic conditions.