Further information for Goobay 93547 Cat6 Patch Cable 1m S/FTP transparent
General
Degree of protection
S/FTP (PiMF)
Cable type
Tubular cable
Connection
RJ45 connector (8P8C)
Cable length
1 m
Specification
CAT 6
Conductor, material
CU (Copper)
AWG
28
Shielding class
S/FTP (PiMF)
Number of shields
2
Type 1, shielding
Film (Alu) PiMF
Type 2, shielding
Braided (Alu)
Pair sequence
EIA/TIA 568B
Contact gold plating
3 µm
Colour
Transparent
LSZH-compliant
Pin retention protection
Slimline strain relief
Length indication on ferrule
The Goobay CAT 6 patch cable is a double-shielded network cable for use in local area networks (LAN). It features two RJ45 connectors (8P8C) at both ends and is designed for connecting network components such as switches, routers, PCs, or network printers. The cable is equipped with shielding class S/FTP (PiMF), meaning each pair is individually shielded with metallic foil (pairs in metal foil) and additionally features an overall shield made of aluminium braid that encloses the entire cable core. This double shielding ensures high immunity against electromagnetic interference and minimizes crosstalk, which is particularly advantageous in environments with high electromagnetic noise. The cable is CAT 6 tested and thus suitable for data transfer rates up to 1 Gbit/s over a length of 100 meters, with a maximum bandwidth of 250 MHz. The pair sequence follows the EIA/TIA 568B standard, ensuring compatible and standardized cabling.
Applications
This patch cable is suitable for use in office environments, server rooms, home networks, and other indoor areas where reliable and fast data transmission is required. The transparent outer jacket allows visual inspection of the cable condition and facilitates identification in cable management. The shielding class S/FTP (PiMF) makes the cable particularly suitable for environments where electromagnetic interference (EMI) may occur, for example, near motors, transformers, or other electrical devices. The cable construction is designed for indoor use, with LSZH compliance (Low Smoke Zero Halogen) ensuring that only minimal smoke and no toxic halogen compounds are released in case of fire.
Features and Equipment in Detail
The cable features gold-plated contact surfaces (pins) with a thickness of 3 µm, ensuring a stable and corrosion-resistant connection. The RJ45 connectors are equipped with a latch nose protection, which reduces mechanical stress on the connector and extends the service life of the connectors. The slimline strain relief boot is tapered and marked with the cable length, making the cable easily identifiable. The inner conductors are made of copper (CU) with an AWG cross-section of 28, providing sufficient conductivity for the intended data transfer rates. The transparent outer jacket is made of an LSZH-compliant material that releases only minimal smoke and no harmful halogen compounds at high temperatures.
Technology Explained Simply
The shielding class S/FTP (PiMF) means that each of the four wire pairs is individually shielded with metallic foil (PiMF = pairs in metal foil). Additionally, an aluminium braid encloses the entire cable core, resulting in double shielding. This construction reduces electromagnetic interference from external sources and crosstalk between individual wire pairs. The gold-plated contacts ensure a reliable electrical connection that remains stable even after frequent plugging and unplugging. The pair sequence according to EIA/TIA 568B is an international standard that ensures compatibility with other network components.
Compatibility and Accessories
The cable is designed for use with standard RJ45 connectors in networks. It is compatible with all devices that support CAT 6 connections, including switches, routers, network interface cards (NICs), and other LAN components. The shielding class S/FTP (PiMF) meets the requirements for high-quality network cables in environments with high electromagnetic noise. No special accessories are required, as the cable is delivered with pre-installed connectors.
Installation and Mounting
Installation is performed by simply plugging the RJ45 connectors into the corresponding sockets of the network components. The slimline strain relief boot protects the connectors from mechanical stress, especially during frequent connection and disconnection. The transparent outer jacket facilitates visual inspection and identification of the cable in cable management. The length marking on the boot supports orientation during installation. No additional tools or mounting aids are required.
The cable is designed for indoor use, with LSZH compliance ensuring that only minimal smoke and no toxic halogen compounds are released in case of fire. The cable construction is suitable for use in office environments, server rooms, and home networks where reliable and fast data transmission is required. The shielding class S/FTP (PiMF) makes the cable particularly suitable for environments where electromagnetic interference (EMI) may occur, for example, near motors, transformers, or other electrical devices. The cable construction is designed for indoor use, with LSZH compliance ensuring that only minimal smoke and no toxic halogen compounds are released in case of fire.
Operational Advantages
The Goobay CAT 6 patch cable offers reliable data transmission with high speeds and low error rates. The double shielding provides high resistance to interference, which is particularly beneficial in environments with electromagnetic disturbances. The gold-plated contacts ensure a stable connection throughout the entire service life of the cable. The transparent outer jacket and length marking on the boot simplify cable management. LSZH compliance increases safety in case of fire, as only minimal smoke and no harmful halogen compounds are released. The cable construction is suitable for use in office environments, server rooms, and home networks where reliable and fast data transmission is required. The shielding class S/FTP (PiMF) makes the cable particularly suitable for environments where electromagnetic interference (EMI) may occur, for example, near motors, transformers, or other electrical devices. The cable construction is designed for indoor use, with LSZH compliance ensuring that only minimal smoke and no toxic halogen compounds are released in case of fire.