| Design |
| Maximum screen size compatibility | 11.6 " |
Channel T1, T2: for Pt 1000 sensors Measuring range -25...+75 degrees Celsius Resolution 1 degree Celsius (1 degree F) Accuracy 0.5 degrees Celsius Irradiation channel: Measuring ranges 0 - 100 mV, 0 - 200 mV, 0 - 1000 mV Accuracy 3% Channels D1, D2: Max. voltage level 5.5 V Max. frequency 2500 Hz Min. pulse duration 250 ?s Switching threshold LOW 0...0.5 V Switching threshold HIGH 3...5.5 V Current input channel: Measuring ranges 0...20 mA, 4...20 mA Accuracy 5% Connections for 1 radiation sensor (0 - 100 mV, 0 - 200 mV, 0 - 1000 mV) 2 temperature sensors (Pt 1000) 2 freely configurable digital connections 1 analog connection standardized 20 mA current interface 2 RJ45 sockets for RS 485 data connection to the inverters Protection class: IP 20 Type: Sensor Box