| General |
| Degree of protection | RT II |
| Coil voltage | 12 V DC |
| Rated power | 0,170 W |
| Coil resistance | 840 Ohm |
| Max. continuous current | 6 A |
| Max. switching voltage | 400 V AC |
| Max. switching capacity AC1 | 1500 VA |
| Max. switching capacity AC15 | 300 VA |
| 1-phase motor load AC3 | 0,185 kW |
| Minimum switching load | 500 mW (12 V / 10 mA) |
| Contact material | AgNi |
| Response time | 5 ms |
| Reset time | 3 ms |
| Voltage withstand coil/contact | 6 kV (1.2/50 μs) |
| Air and creepage distance | 8 mm |
| Ambient temperature | -40…+85 °C |
| Mechanical life | 10 · 10⁶ Switching operations |
| Electrical life AC1 | 60 · 10³ Switching operations |
| DC operating range | 0,7…1,5 U_N |
| Hold voltage DC | 0,4 U_N |
| Drop voltage DC | 0,05 U_N |
| Construction type | narrow, 5 mm wide |
| Connection type | plug-in / printed circuit board connection |
| Mounting | circuit board or socket series 93 |
| Approval | UL approval for socket/relay combination (on some versions) |
The Finder plug-in/PCB relay type 34.51.7.012.0010 is a narrow, single-pole changeover relay for mounting on printed circuit boards or on sockets of series 93. It is designed for use in industrial applications such as packaging machines, labelling machines, burner and boiler controls, as well as in electronic assemblies and programmable controllers. The relay features a compact design with a width of 5 mm, making it suitable for space-saving installations. It operates with a coil voltage of 12 V DC and has a rated power of 0.170 W, representing a low energy consumption rating. The contact materials consist of AgNi, a cadmium-free material that ensures high switching capacity and long service life.
Applications
The relay is intended for use in various industrial and electronic systems, particularly in installations requiring reliable and compact switching functions. Typical applications include control of packaging and labelling systems, regulation of burners and boilers, and integration into electronic assemblies and programmable controllers. The protection class RT II ensures sufficient insulation between coil and contact, which is important for safety in electrical installations.
Functions and Features in Detail
The relay provides a single-pole changeover with a maximum continuous current of 6 A and a maximum switching voltage of 400 V AC. The maximum switching capacity is 1500 VA for AC1 operation and 300 VA for AC15 operation (230 V AC). For single-phase motor loads (AC3 operation), a power of 0.185 kW is permitted. The AgNi contact materials enable high switching capacity and long service life. The coil is designed for an operating voltage of 12 V DC, with an operating range of 0.7 to 1.5 times the nominal voltage. The holding voltage is 0.4 times the nominal voltage, and the release voltage is 0.05 times the nominal voltage.
Technology Explained Simply
The low coil power of 0.170 W reduces energy consumption and enables efficient actuation. The pickup and release time are 5 ms and 3 ms respectively, ensuring fast response to switching operations. The voltage withstand between coil and contact is 6 kV (1.2/50 μs), ensuring high electrical insulation. The creepage and clearance distance is 8 mm, enhancing safety at high voltages. The ambient temperature range is from -40 °C to +85 °C, making the relay suitable for a wide range of operating conditions.
Compatibility and Accessories
The relay can be mounted directly onto printed circuit boards or onto sockets of series 93, which are equipped with screw, spring clamp, or Push-In terminals. Compatible sockets include, for example, types 93.51.0.024, 93.63.7.024, 93.61.7.024, 93.01.7.024, 93.01.0.024, 93.11, 93.51.7.024, 93.60.7.024, and 93.66.7.024. These sockets allow flexible mounting on support rails (35 mm according to EN 60715) and offer various connection types for different requirements.
Mounting and Installation
Mounting is done either directly onto the printed circuit board or via a socket of series 93. The sockets offer various connection types such as screw connection, spring clamp terminal, or Push-In terminal, enabling flexible and secure connections to other components. Mounting on support rails (35 mm) is also possible, facilitating integration into existing control panels.
Operational Advantages
The relay features a high mechanical life of 10 million switching operations (DC) and an electrical life of 60,000 switching operations (AC1). The low coil power and fast pickup time ensure efficient and reliable switching performance. The protection class RT II ensures sufficient electrical insulation, and the high voltage withstand between coil and contact enhances safety. The operating temperature range of -40 °C to +85 °C makes the relay suitable for a wide variety of operating conditions.