| General |
| Degree of protection | IP66 |
| Explosion protection approval | II 2G Ex de IIB + H2 T6 Gb |
| Loudness | 110 dB(A) |
| Number of tones | 32 |
| Alarm levels | 2 |
| Nominal voltage | 230 V |
| Voltage range | 80-265 V AC |
| Type of current | AC |
| Electricity consumption | 0,093 A |
| Temperature range | -50 to +60 °C |
| Temperature class (gas) | T6 |
| Max. surface temperature (dust) | T85°C |
| Housing material | Aluminium |
| Housing property | seawater resistant |
| Protection principle | d, e |
| MTBF | 2181942 Operating hours |
The FHF Ex-sounder dEV20, type 21591007, is an explosion-protected signaling device for use in hazardous areas with gas and dust explosion risks. It is approved for zones 1 and 2 (gas) as well as 21 and 22 (dust) and is suitable for indoor and outdoor applications. The device features a protection rating of IP66, ensuring dust-tight and watertight conditions even under direct spray water and short-term immersion. It is designed for operation in environments with temperatures from -50 °C to +60 °C, providing high operational safety under extreme climatic conditions.
Applications
The sounder is designed for industrial applications in explosion-hazardous areas, particularly in the chemical, petrochemical, pharmaceutical, and processing industries. It is used to provide an acoustic warning in case of alarms such as fire, gas leakage, or other hazardous situations. The approval according to ATEX (II 2G Ex de IIB + H2 T6 Gb and II 2D Ex tb III C T85°C Db) ensures its use in gas and dust zones in accordance with European explosion protection directives. The applications include both indoor and outdoor installations where high mechanical and climatic resistance is required.
Functions and Equipment in Detail
The device produces a sound level of approximately 110 dB(A), with one source indicating a value of 115 dB. The acoustic signaling is provided via 32 different signal tones, which can be used for various alarm types or warning levels. A two-stage alarm mode allows differentiation between warning and emergency alarms. The signals are designed to be clearly perceptible even in noisy industrial environments. The housing is made of seawater-resistant aluminum, ensuring high corrosion resistance, especially in marine or humid environments.
Technology Explained Simply
The sounder operates with a nominal voltage of 230 V AC and is designed for a voltage range of 80 to 265 V AC, enabling flexible integration into existing power supplies. The current consumption is 0.093 A. The protection principle combines the methods
d (explosion-proof pressure resistance) and
e (increased safety), enabling the device to withstand internal pressure in case of an explosion and prevent the spread of sparks or hot gases. The temperature class T6 indicates that the maximum surface temperature of the device is below 85 °C, which is important for use in gas environments with low ignition temperatures. For dust environments, a maximum surface temperature of T85°C is specified.
Compatibility and Accessories
The sounder is designed for use in explosion-protected installations and can be integrated into existing alarm and safety systems. It is operated with standard mains voltage and does not require a special power supply. Its use in combination with other signaling devices, such as optical warning lights, is possible, provided the respective approvals and protection categories are compatible. The exact mounting and wiring must be carried out according to the technical specifications of the respective installation and applicable standards.
Mounting and Installation
Mounting is carried out at a suitable, accessible location that meets the requirements of the respective explosion zone. The device is intended for wall or ceiling mounting. Fixing is done via integrated mounting surfaces. The electrical connection is made via the designated terminal clamps. Installation must be performed by qualified specialists who comply with applicable regulations and safety requirements. Dimensions are 144 mm (width), 345 mm (height), and 162 mm (depth), although one source cites alternative dimensions of 110 mm (W), 243 mm (H), and 110 mm (D). The MTBF (mean time between failures) is 2,181,942 operating hours, indicating high reliability.
Advantages in Operation
The sounder offers high sound level and a wide selection of signal tones to clearly distinguish between different alarm types. The robust construction from seawater-resistant aluminum and the IP66 protection rating ensure long service life even under harsh environmental conditions. The approval for gas and dust zones significantly expands the range of applications. Operational safety is supported by the d/e protection principle and temperature classes T6 (gas) and T85°C (dust). The high MTBF underscores the device’s reliability in continuous operation.