| General |
| Degree of protection | IP20 |
| Number of safety outputs | 2 |
| Output type | semiconductor outputs |
| Safety category | 4 |
| Performance level | e |
| Norm | EN ISO 13849-1 |
| Maximum number of connected switches | 20 |
| Function | short-circuit monitoring |
The safety switch CES-AR-C01-CH-SA from Euchner is a modular safety relay with integrated evaluation electronics, designed for use in industrial safety systems. It is used to monitor up to 20 safety switches in series and ensures reliable shutdown of machines or systems in case of failure. The integrated electronics monitor not only the switch positions but also the cross-connection between switches to detect unauthorized bypass connections. The outputs are designed as semiconductor outputs, enabling high switching speed and low maintenance. The device complies with Category 4 / PL e according to EN ISO 13849-1, ensuring high safety performance in critical applications. The Multicode function allows flexible coding of switches to facilitate assignment and identification within the system.
Applications
The safety switch is intended for use in industrial machines and systems, particularly in areas with high safety requirements, such as in manufacturing, packaging, or automation technology. It is suitable for monitoring emergency stop switches, door contacts, light grids, or other safety switches arranged in series. The ability to monitor up to 20 switches makes it especially suitable for more complex systems with multiple safety points.
Functions and Equipment in Detail
The integrated evaluation electronics continuously monitor the states of the connected safety switches. If a contact opens or a cross-connection occurs, the safety output is immediately deactivated to prevent hazards. The cross-connection monitoring detects when two switches are illegally connected, which represents a potential bypass situation. The two safety outputs are designed as semiconductor outputs, enabling high switching speed and long service life. The Multicode function allows individual coding of switches to ensure unique assignment within the system.
Technology Explained Simply
The safety function is based on continuous monitoring of switch states. The integrated electronics check whether all connected switches are in the correct position (closed). If any switch opens or a cross-connection occurs, the output is immediately switched off. The semiconductor outputs ensure fast and reliable switching without mechanical wear parts. Category 4 / PL e according to EN ISO 13849-1 means the device is suitable for applications with the highest safety requirements, where failure of the safety function could have serious consequences.
Compatibility and Accessories
The safety switch is designed for use with other safety switches from manufacturer Euchner, particularly models supporting the Multicode function. Connections are made via standardized interfaces, enabling easy integration into existing safety architectures.
Mounting and Installation
Mounting is carried out in the usual manner within an enclosure or control unit. Connections are clearly labeled, and electrical connections are made via standard terminals. Installation requires no special tools or additional components.
Advantages in Operation
Using the safety switch CES-AR-C01-CH-SA provides high safety performance through continuous monitoring and rapid response in case of failure. The integrated electronics reduce the number of required components and simplify installation. The Multicode function enables flexible and secure configuration of switches, facilitating maintenance and diagnostics. The semiconductor outputs ensure long service life and low maintenance costs.