. 1 main fuse, circuit breaker C 50 / 3-pole
. 1 emergency stop switch 3 x 63 A as main switch with undervoltage release,
lockable in the 0 position
. 1 emergency stop button
. 1 junction box with plug for external emergency stop button connection
. 1 residual current circuit breaker 4 x 63 A, tripping current 30 mA, for
alternating residual currents and pulsating direct residual currents
. 3 phase control lights L1, L2, L3
. 1 reversing switch 3 x 63 A
. 1 device fuse 5 x 20 mm, 2 A
. 1 digital multi-function measuring device with 3 x 3-digit display
. The following measured values can be displayed at the same time:
- Phase currents L1, L2, L3
- Phase voltages L1-N, L2-N, L3-N
- Chained voltages L1-L2, L2-L3, L1-L3
- Active power, reactive power, apparent power
- Frequency, power factor
. 3 current transformers 60/5 A
. 1 circuit breaker C 16 A, 1-pole
. 1 earthed socket 16 A, 230 V (measuring socket)
. 1 CEE socket 16 A, 3-pole, 230 V
. 3 circuit breakers C 16 A, 1-pole
. 1 USB charging station type A and C
. 1 CEE socket 16 A, 5-pole, 400 V
. 3 circuit breakers C 32 A, 1-pole
. 1 CEE socket 32 A, 5-pin, 400 V
. 1 CEE socket 63 A, 5-pin, 400 V
. 5 terminal sockets 63 A, L1, L2, L3, N, PE
. 1 star-delta switch 15 KW
. 7 terminal sockets 63 A
. 1 circuit breaker C 16 A, 1-pin
. 1 earthed socket 16 A, 230 V (work socket)
. 1 safety transformer VDE 0551, 230 V/8-42-50 V/150 VA~
. 1 circuit breaker C 1 A, 1-pin, primary for transformer
. 1 circuit breaker C 4 A, 1-pin, secondary for transformer
. 1 single-phase toroidal transformer 230 V/0-230 V/3.15 A
. 1 ammeter 0 - 4/8 A, 72 x 72 mm, class 1.5
. 1 voltmeter 0 - 20 V, AC, 72 x 72 mm, class 1.5
. 1 voltmeter 0 - 60 V, AC, 72 x 72 mm, class 1.5 .
1 voltmeter 0 - 20 V, DC, 72 x 72 mm, class 1.5 .
1 voltmeter 0 - 60 V, DC, 72 x 72 mm, class 1.5
. 1 voltmeter switch 20 V AC-60 V AC-0-60 V DC-20 V DC
. 2 safety sockets for taking the adjustable
alternating voltage 0 - 50 V
. 1 silicon bridge rectifier 10 A, residual ripple 48 %
. 2 safety sockets for taking the adjustable direct voltage
0 - 50 V
. 1 continuity test lamp 24 V~
. 2 safety sockets for optical continuity testing
. 1 buzzer 8 V~ for acoustic continuity testing
. 2 safety sockets for acoustic continuity testing
. 1 mains VDE 0701-VDE 0702 switch for switching the
socket outlets to protective measure testing
. 1 device tester