Further information for Elektra Tailfingen PST 4E-LCD - ET PST 4E test panel LCD BUILT
1 main fuse, circuit breaker C 50 / 3-pole
. 1 emergency stop switch 3 x 63 A as main switch with
undervoltage release, lockable in the 0 position
. 1 emergency stop button
. 1 junction box with plug for external emergency stop button connection
. 1 residual current circuit breaker 4 x 63 A, tripping current 30 mA, for
alternating residual currents and pulsating direct residual currents
. 3 phase control lights L1, L2, L3
. 1 reversing switch 3 x 63 A.
1 voltmeter switch for measuring chain and
phase voltages
. 1 voltmeter 0 - 500 V, 72 x 72 mm, class 1.5
. 1 ammeter 0 - 1/2 A, 72 x 72 mm, class 1.5, with
overload protection
. 1 ammeter 0 - 6/12 A, 72 x 72 mm, class 1.5, with
overload protection
. 1 ammeter 0 - 25/50 A, 72 x 72 mm, class 1.5, with
overload protection
. 1 ammeter 0 - 60/120 A, 72 x 72 mm, class 1.5
. 1 ammeter switch 0 - 1 A, 0 - 6 A, 0 - 25 A, 0 - 60 A
. 1 measuring point switch for ammeter 0-L1-L2-L3
. 1 circuit breaker C 16 A, 1-pole
. 1 protective contact socket 16 A, 230 V (measuring socket)
. 1 CEE socket 16 A, 3-pole, 230 V
. 3 circuit breakers C 16 A, 1-pole
. 1 USB charging station type A and type C
. 1 CEE socket 16 A, 5-pole, 400 V
. 3 circuit breakers C 32 A, 1-pole
. 1 CEE socket 32 A, 5-pole, 400 V
. 1 CEE socket 63 A, 5-pole, 400 V
. 5 terminal sockets 63 A, L1, L2, L3, N, PE
. 1 star-delta switch 15 KW
. 7 terminal sockets 63 A
. 1 circuit breaker C 16 A, 1-pole
. 1 protective contact socket 16 A, 230 V (work socket)
. 1 safety transformer VDE 0551, 230 V/3-5-8-12-24-42-50 V/
100 VA~
. 1 device circuit breaker 0.8 A, primary for transformer
. 1 device circuit breaker 2 A, secondary for transformer
. 1 device circuit breaker 4 A, secondary for transformer
. 1 low voltage switch 0-3-5-8-12-24-42-50 V~
. 1 voltmeter 0 - 10 V, 72 x 72 mm, class 1.5
. 1 voltmeter 0 - 60 V, 72 x 72 mm, class 1.5
. 3 safety sockets for measuring low voltage 0 - 50 V~
. 1 continuity test light 24 V~
. 2 safety sockets for optical continuity testing
. 1 buzzer 8 V~ for acoustic continuity test
. 2 safety sockets for acoustic
continuity testing
. 1 mains VDE 0701-VDE 0702 switch for switching the
socket outlets to protective measure testing
. 1 device tester