Eaton EP-501043, EAN: 9010653032755

Moeller Electric SPZT123-300/3+NPE-S surge protection device

Moeller Electric SPZT123-300/3+NPE-S surge protection device

Lieske Part No. 677576
Mfg Part No EP-501043
EAN-Code 9010653032755
Manufacturer Eaton
Here only 549,93 EUR
654,42 EUR incl. VAT

Further information for Moeller Electric SPZT123-300/3+NPE-S surge protection device

General
Degree of protectionSPD Type T1+2+3
Test classI, II, III
StandardsDIN VDE 0100-534, IEC 61643-1, IEC 61643-11: 2011, EN 61643-11: 2012+A11: 2018
Surge protection classIII and IV
Mountingon 40-mm busbar
Functionleakage current-free, integrated fuse for SmartMeterGateway and APZ
The surge protection device SPZT123-300/3+NPE-S from Eaton is a SPD Type T1+2+3 for use in the supply-side connection area of the meter cabinet. It is specifically designed for mounting on a 40-mm busbar and serves to protect consumer installations from transient overvoltages caused by direct and indirect lightning strikes as well as switching operations. The device meets the requirements of DIN VDE 0100-534 and is certified for test classes I, II, and III according to IEC 61643-1. It also complies with the standards IEC 61643-11: 2011, EN 61643-11: 2012+A11: 2018, and is suitable for lightning protection classes III and IV according to IEC 62305. The surge arrester is leakage current-free and features an integrated fuse that protects the SmartMeterGateway and the APZ.

Applications
This overvoltage protection is intended for use in electrical installations in the distribution area, particularly in the meter cabinet. It protects downstream consumer installations from transient overvoltages caused by lightning discharges or switching operations in the network. Mounting is on a 40-mm busbar, enabling standardized installation in distribution enclosures. The application is in the supply-side area, i.e., before the meter, to protect the entire downstream installation.

Functions and Equipment in Detail
The surge arrester provides combined protection for test classes I, II, and III, meaning it can divert both high lightning currents (T1) and smaller transient overvoltages (T2 and T3). The integrated fuse ensures protection of the SmartMeterGateway and the APZ, thereby safeguarding against overloads and short circuits. The leakage current-free design prevents unwanted currents during operation, which is important for the safety and functionality of the installation.

Technology Explained Simply
A SPD Type T1+2+3 is an overvoltage protection device that combines multiple protection levels in a single unit. Test class I protects against direct lightning strikes, test class II against indirect lightning strikes, and test class III against switching surges. The standards IEC 61643-11 and EN 61643-11 define the requirements for electrical characteristics and testing procedures. Lightning protection classes III and IV according to IEC 62305 refer to the maximum permissible lightning currents and the required protection. The integrated fuse in the device protects downstream equipment such as the SmartMeterGateway and the APZ from overloads.

The integrated fuse in the device protects downstream equipment such as the SmartMeterGateway and the APZ from overloads.

Compatibility and Accessories
The device is designed for use in distribution enclosures with a 40-mm busbar. It is compatible with the standards DIN VDE 0100-534, IEC 61643-1, IEC 61643-11: 2011, EN 61643-11: 2012+A11: 2018, and IEC 62305. It is designed for lightning protection classes III and IV, enabling high protection performance in the distribution area. The integrated fuse is specifically intended for protecting the SmartMeterGateway and the APZ.

Mounting and Installation
Mounting is on a 40-mm busbar in the supply-side connection area of the meter cabinet. Fixing is done using the designated mounting elements designed for the standard busbar. Installation is carried out before the meter to protect the entire downstream installation. Wiring is done according to the requirements of the standards and the specific installation configuration.

Operational Advantages
The surge arrester provides comprehensive protection against transient overvoltages caused by lightning strikes or switching operations. The integrated fuse protects the SmartMeterGateway and the APZ from overloads. The leakage current-free design prevents unwanted currents during operation. Compliance with the standards DIN VDE 0100-534, IEC 61643-1, IEC 61643-11: 2011, EN 61643-11: 2012+A11: 2018, and IEC 62305 ensures safe and reliable operation in the distribution area. Mounting on the 40-mm busbar enables standardized and easy installation in the meter cabinet.
This is an offer of:

Lieske Elektronik e.K.

Reutener Str. 10
79279 Vörstetten

https://industry-electronics.com
Tel. 07666/88499-0
Fax. 07666/88499-111

Diesen Artikel finden Sie unter:
industry-electronics.com/artikel/677576
qrcode für Moeller Electric SPZT123-300/3+NPE-S surge protection device