Further information for Eaton EATS16 ATS 16 redundant switch 1U
Certificates
Certification
IEC/EN 62310-1, IEC/EN 60950-1, IEC/EN 62310-2, CE
Design
PDU types
Basic
Form factor
Rackmount
Rack capacity
1U
Mounting
Horizontal
Product colour
Black
Display
LCD
Rack mounting
Features
LED indicators
Packaging content
Rack mount kit
Ports & interfaces
AC outlets quantity
9 AC outlet(s)
Power plug
C20 coupler
AC outlet types
C13 coupler, C19 coupler
Master AC outlets quantity
9
Power
Nominal input voltage
230 V
AC input frequency
50 - 60 Hz
Maximum current
16 A
Maximum input current per phase
16 A
Weight & dimensions
Width
430 mm
Depth
250 mm
Height
43 mm
Weight
3.3 kg
The Eaton EATS16 is a rackmount PDU (Power Distribution Unit) in standard design, designed for use in server racks and IT infrastructures. With a rack capacity of 1U and horizontal mounting, it offers a compact yet powerful power distribution solution. The device features an LCD display and is finished in black, making it visually compatible with typical data center and server environments. The PDU is designed for use in 19-inch racks and enables efficient power supply to multiple devices via a central input.
Rack mounting and physical design
The Eaton EATS16 is designed as a rackmount module and occupies a height of 1U, making it ideal for use in standard 19-inch racks. The horizontal mounting allows for easy installation and integration into existing rack systems. Dimensions are 430 mm (width), 250 mm (depth), and 43 mm (height), with the device weighing 3.3 kg.
Connectors and power distribution
The PDU features a total of 9 AC outlets, all configured as master AC outlets. The outlets are equipped with C13 and C19 connectors, enabling flexible connection to a wide range of IT and network devices. The input is fitted with a C20 connector, which connects to a suitable power source. The maximum current rating is 16 A, with a nominal input voltage of 230 V. The input frequency range is 50 to 60 Hz, ensuring compatibility with various power grids.
Display and monitoring
An integrated LCD display enables visual monitoring of operational states. Additionally, LED indicators show the status of individual outlets. These features support maintenance and fault diagnosis by making the operational status of the PDU and connected devices visible. The indicators are designed for operation in data centers and server rooms, where quick identification of failures or load distribution is important.
Certification and safety
The Eaton EATS16 meets certification requirements according to IEC/EN 62310-1, IEC/EN 60950-1, IEC/EN 62310-2 and carries the CE mark. These certifications guarantee the safety and reliability of the device in use, particularly regarding electrical safety, overload protection, and electromagnetic compatibility. Compliance with these standards makes the PDU suitable for use in professional IT environments.
Applications and compatibility
The PDU is designed for use in data centers, server rooms, and IT infrastructures where reliable and monitorable power distribution is required. The combination of 9 outlets, C13 and C19 connectors, and the LCD display makes it particularly suitable for powering network devices, servers, and storage solutions. The horizontal mounting and 1U size enable efficient space utilization in confined rack environments.
Operation and maintenance
Operation of the Eaton EATS16 is performed via the integrated indicators and LCD screen, which display the status of the power supply and individual outlets. Maintenance is simplified due to the clear indicators and easy mounting. Power supply is via the C20 input, which connects to a suitable network component or UPS.
Operational advantages
The Eaton EATS16 provides reliable power distribution with integrated monitoring. The combination of LCD display and LED indicators enables quick diagnosis of operational states. The 9 master AC outlets with C13 and C19 connectors ensure flexible connection of various devices. Certifications according to IEC/EN standards and the CE mark guarantee safety and reliability in professional use. The horizontal 1U mounting optimizes space requirements in server racks.