Eaton 285602, EAN: 4015082856021

Moeller 285602 PFR-W-105 converter for RCD relay

Industrial Material > Control devices / Pilot devices > Breakers and disconnectors

Moeller 285602 PFR-W-105 converter for RCD relay

Lieske Part No. 932577
Mfg Part No 285602
EAN-Code 4015082856021
Manufacturer Eaton
Here only 563,80 EUR
670,92 EUR incl. VAT

Further information for Moeller 285602 PFR-W-105 converter for RCD relay

General
ManufacturerEaton
Inner diameter105 mm
UtilizationFor RCD relays
CompatibilityNZM1, NZM1-4, N1, N1-4, NZM2, NZM2-4, N2, N2-4, NZM3, NZM3-4, N3, N3-4, NZM4, NZM4-4, N4-4
Mounting methodScrew mounting
Alternative mountingmounting clip for DIN rail mounting
Approvalnot UL/CSA-approved
The article Eaton PFR-W-105 is a current transformer for RCD relays, developed as optional accessory for the NZM circuit breaker series. It is used for monitoring earth fault currents in electrical installations and enables the integration of RCD protection functions into existing switchgear. The transformer is designed for use in industrial and commercial installations where reliable earth fault detection is required. It is used in combination with RCD relays to trigger disconnection of the power supply in case of earth fault currents, thus protecting personnel and equipment from damage.

Applications

The transformer is suitable for a wide range of circuit breaker types from the NZM series, including models such as NZM1, NZM1-4, N1, N1-4, NZM2, NZM2-4, N2, N2-4, NZM3, NZM3-4, N3, N3-4, NZM4, NZM4-4, and N4-4. These breakers are used in industrial control systems, distribution enclosures, and electrical installations where modular expansion of protection functions is required. The application is particularly suitable for installations requiring high safety standards for earth fault detection, such as production plants, machine controls, or buildings with increased fire or electrical risk.

Functions and Equipment in Detail

The transformer features an inner diameter of 105 mm, allowing cables with a corresponding outer diameter to be passed through. Mounting is done via screw mounting, with an alternative option of a mounting clip for DIN rail mounting. This modular mounting design enables flexible and easy integration into existing switchgear. The device is used in combination with RCD relays, which monitor the earth fault current and trigger disconnection when a predefined threshold is exceeded.

Technology Explained Simply

The current transformer operates on the principle of inductive current measurement. It encloses the conductor and detects the magnetic flux generated by the current flow in the conductor. This measurement enables detection of earth fault currents, which arise as the difference between incoming and outgoing current. The technology is particularly suitable for applications requiring high sensitivity and reliability in earth fault detection. The specification that the transformer diameter must be 1.5 times larger than the outer diameter of the conductor ensures that the conductor is fully positioned inside the transformer, preventing measurement errors due to insufficient coverage.

Compatibility and Accessories

The transformer is specifically developed for the NZM circuit breaker series and can be combined with various models from this series. Compatibility includes both 3-pole and 4-pole breaker models. The screw mounting is supplied as standard accessory, with an alternative mounting clip available for DIN rail mounting. Use with RCD relays is intended, with the exact relay selection depending on the requirements of the specific installation. Combination with other NZM series components enables modular expansion of protection functions.

Mounting and Installation

Mounting is done using the supplied screw mounting, enabling secure attachment to the switchgear. Alternatively, a mounting clip for DIN rail mounting can be used, allowing quick and flexible installation in enclosures. Installation requires passing the conductor through the inner diameter of the transformer, with the technical guideline specifying that the transformer diameter must be 1.5 times larger than the outer diameter of the conductor. This ensures the conductor is fully positioned inside the transformer and reliable measurement is guaranteed.

Advantages in Operation

Using the transformer provides flexible expansion of protection functions in existing installations. The modular design enables easy integration into various switchgear systems without requiring extensive modifications. Reliable earth fault detection increases safety in electrical installations. Combination with RCD relays enables precise and rapid response to earth fault currents, enhancing safety for personnel and equipment. Use in combination with the NZM series offers high compatibility and enables standardized equipment of switchgear systems.
This is an offer of:

Lieske Elektronik e.K.

Reutener Str. 10
79279 Vörstetten

https://industry-electronics.com
Tel. 07666/88499-0
Fax. 07666/88499-111

Diesen Artikel finden Sie unter:
industry-electronics.com/artikel/932577
qrcode für Moeller 285602 PFR-W-105 converter for RCD relay