| General |
| Manufacturer | Eaton |
| Application | current transformer for RCD relay |
| Inner diameter | 70 mm |
| Compatibility | NZM1, NZM1-4, N1, N1-4, NZM2, NZM2-4, N2, N2-4, NZM3, NZM3-4, N3, N3-4, NZM1-NA, NZM2-NA, NZM3-NA |
| Mounting method | Screw mounting |
| Alternative mounting method | mounting clip for DIN rail mounting |
| Approval | not UL/CSA-approved |
The article
PFR-W-70 from
Eaton is a current transformer for residual current relays (RCD relays) and serves as optional accessory for the circuit breaker series
NZM. It enables the integration of RCD protection functions into existing switchgear and is particularly used in installations with increased safety requirements, where reliable protection against indirect contact voltages is necessary. The transformer is designed for use in industrial and commercial electrical installations, where it is mounted on circuit breakers of the NZM series to detect fault currents and trigger the breaker to trip when a predefined threshold is exceeded.
Applications
The
PFR-W-70 is suitable for use in electrical installations with rated voltages up to 1000 V and rated currents up to 630 A, as commonly found in industrial electrical engineering. It is used in switchgear with circuit breakers of types NZM1, NZM2, NZM3, as well as their 4-pole variants (such as NZM1-4, NZM2-4, NZM3-4) and the corresponding N-models (N1, N2, N3). Compatibility also includes the NA variants of the NZM series. The transformer is designed for use in installations that are not UL/CSA-approved, indicating a specific certification landscape, particularly for markets outside North America.
Functions and Equipment in Detail
The
current transformer is specifically designed for RCD relays and enables the measurement of fault currents, which arise from the difference between incoming and outgoing current. It is directly mounted on the circuit breaker and encloses the through-conductors, with the inner diameter of the transformer being 70 mm. This value is critical for selecting the appropriate transformer, as the diameter of the current transformer must be at least 1.5 times larger than the outer diameter of the conductor being passed through, to ensure safe and accurate measurement. Mounting is typically done via
screw mounting, with an alternative option being a
mounting clip for DIN rail mounting. This flexibility allows for easy integration into existing switchgear with different mounting concepts.
Technology Explained Simply
The
PFR-W-70 operates on the principle of a current transformer, where a magnetic field is generated by the conductor passing through it. In the event of a fault current, caused by insulation failure or contact with earth, an asymmetry arises between incoming and outgoing current. This difference is detected by the transformer and transmitted to the RCD relay, which then triggers the breaker to trip. The
rated voltage of the transformer is not explicitly specified, but it is designed for use in installations up to 1000 V, as is typical for compatible circuit breakers.
Compatibility and Accessories
The transformer is specifically designed for the
NZM series from Eaton and can be mounted on various models of this series, including NZM1, NZM2, NZM3, and their 4-pole variants, as well as the N-models. It is not intended for UL/CSA approvals, meaning it is used in installations that do not fall under these certification guidelines. As an accessory, a
mounting clip for DIN rail mounting is available, enabling an alternative mounting method. The use of the transformer requires adherence to the technical guideline that the diameter of the transformer must be at least 1.5 times larger than the outer diameter of the conductor being passed through.
Mounting and Installation
Mounting is done either via the included
screw mounting or via the optional
mounting clip for DIN rail mounting. Installation requires correct positioning of the transformer around the through-conductors, taking into account the dimensions of the conductors. The mounting is modular and flexible, allowing the transformer to be easily attached to existing breakers. Adherence to the technical guideline regarding the diameter ratio is essential for the functionality of the RCD protection.
Advantages in Operation
The use of the
PFR-W-70 provides reliable fault current detection in industrial installations, thereby increasing the safety of the installation and the operators. The modular design enables easy integration into existing switchgear without extensive modifications. Compatibility with a wide range of NZM circuit breakers increases flexibility in planning and maintaining switchgear. The use of RCD protection functions is particularly important in installations with increased risk of electrical hazards, as commonly found in industry and commerce.