| Features |
| Circuit breaker type | Miniature circuit breaker |
| Type | Type B |
| Number of poles | 3 |
| International Protection (IP) code | IP20, IP40 |
| Operational conditions |
| Operating temperature (T-T) | -25 - 75 °C |
| Power |
| Rated current | 16 A |
| Rated voltage | 240 V |
| Weight & dimensions |
| Depth | 70.5 mm |
The FAZ-B16/3 circuit breaker from Eaton is a miniature circuit breaker designed for use in industrial and extended commercial installations. With a rated current of 16 A and a nominal voltage of 240 V, it provides protection for electrical circuits and consumers against overload and short-circuit. The switch features a Type B tripping characteristic, suitable for applications with medium inrush currents, such as those occurring with electric motors or heating appliances. It is 3-pole, making it suitable for three-phase AC installations up to 240 V AC. The protection ratings IP20 and IP40 ensure protection against finger contact and against solid foreign objects as well as splashing water, allowing safe use in indoor environments and protected areas. The operating temperature ranges from -25 °C to 75 °C, enabling use in various environmental conditions. The depth of the device is 70.5 mm, which must be considered when planning installation in distribution boxes.
Applications
The FAZ-B16/3 is intended for use in industrial and extended commercial installations where reliable current protection is required. It is particularly suitable for systems operating electrical devices with medium inrush currents, such as pumps, fans, or heating systems. The 3-pole design makes it especially suitable for three-phase power networks found in production facilities, warehouses, or office buildings with higher electrical loads. The protection ratings IP20 and IP40 limit use to indoor spaces or protected outdoor areas where there is no direct moisture or dust exposure.
Functions and Equipment in Detail
The switch operates on the principle of a miniature circuit breaker (MCB) with a Type B tripping characteristic. This characteristic ensures that the switch trips within seconds when the current exceeds 3 to 5 times the rated current (i.e., from approximately 48 A to 80 A), preventing short circuits. For overloads exceeding the rated current of 16 A but below the short-circuit range, the disconnection occurs with a time-delayed response to limit thermal stress on the conductors. The 3-pole construction allows simultaneous disconnection of all three phases, which is crucial for safety in three-phase installations. The protection ratings IP20 and IP40 protect against mechanical impacts and limited moisture, enabling safe operation in dry indoor environments.
Technology Explained Simply
A circuit breaker like the FAZ-B16/3 protects electrical circuits and connected devices from damage caused by overload or short-circuit. It detects excessive current flow and automatically disconnects the circuit. The Type B tripping characteristic is specifically designed for systems with medium inrush currents, which occur during the start-up of motors or other inductive loads. The 3-pole design ensures that all three phases of a three-phase circuit are disconnected simultaneously, providing secure isolation. The IP20 rating protects against finger contact, while IP40 adds protection against splashing water and solid foreign objects, enabling use in protected indoor environments. The operating temperature range of -25 °C to 75 °C allows use in environments with varying climatic conditions, such as production halls or air conditioning systems.
Compatibility and Accessories
The FAZ-B16/3 is designed for use in distribution boxes with Euro-Vario busbars. Compatible busbars include, for example, EVG-16/3PHAS/12MODUL/HI, EVG-16/2PHAS/4MODUL/HI, or EVG-16/1PHAS/2MODUL, each with a rated current of 100 A. These busbars enable modular mounting and provide space for multiple switches. Additional auxiliary switches such as the FAZ-XAM002 (2 changeover contacts) or FAZ-XHINW1 (1 changeover contact) are available for remote monitoring or control of the switch. An operating current tripping unit FAZ-XAA-C-110-415VAC and a remote switching module FAZ/FIP-XAWM (220–240 V AC) are also available as accessories to extend the switch’s functionality.
Mounting and Installation
The switch is mounted in standard distribution boxes with Euro-Vario busbars. Installation is done by snapping into the busbar, with the depth of 70.5 mm needing to be considered when planning the box depth. The 3-pole design requires correct assignment of phase conductors to ensure safe and orderly power distribution. The protection ratings IP20 and IP40 require that the switch be installed in dry indoor areas or protected zones to maintain the intended protection functions. The operating temperature range of -25 °C to 75 °C must be considered when selecting the installation location to ensure reliable performance.
Advantages in Operation
The FAZ-B16/3 provides reliable protection for electrical installations with a rated current of 16 A. The Type B tripping characteristic ensures appropriate response to overloads and short circuits, preventing damage to conductors and devices. The 3-pole design ensures secure disconnection in three-phase installations. The protection ratings IP20 and IP40 offer sufficient protection for indoor and protected outdoor environments. Compatibility with Euro-Vario busbars enables flexible and modular installation. The operating temperature range of -25 °C to 75 °C allows use in various environments, increasing operational flexibility. Compliance with standards for miniature circuit breakers ensures safe and reliable performance during operation.