Eaton 278606, EAN: 4015082786069

Moeller 278606 Circuit Breaker 1A 1p S-Char

Installation > Modular devices / equipment installation > Circuit breaker

Moeller 278606 Circuit Breaker 1A 1p S-Char

Lieske Part No. 230701
Mfg Part No 278606
EAN-Code 4015082786069
Manufacturer Eaton
Here only 305,63 EUR
363,70 EUR incl. VAT

Further information for Moeller 278606 Circuit Breaker 1A 1p S-Char

Features
Circuit breaker typeMiniature circuit breaker
TypeType S
Number of poles1
International Protection (IP) codeIP20
Power
Rated current1 A
Rated voltage240 V
The FAZ-S1/1 circuit breaker from Eaton is a miniature circuit breaker designed for use in industrial and extended commercial installations. With a rated current of 1 A and a rated voltage of 240 V, it provides protection for electrical lines and loads in single-phase networks. The switch features a Type S tripping characteristic, which enables delayed thermal tripping during short-term current surges, thereby enhancing operational safety. The 1-pole configuration makes it suitable for applications where only one phase needs to be protected. The International Protection Rating IP20 ensures protection against contact with fingers and against solid foreign objects, but not against water or dust – thus, the switch is intended for indoor use where no special environmental conditions such as humidity or contamination are present.

Applications

The FAZ-S1/1 is used in electrical distributions where precise current limitation and protective functions are required for sensitive equipment or specific loads. Typical application fields include lighting circuits, small appliances, or control systems where stable and reliable power supply is necessary. The Type S characteristic is particularly suitable for installations with high inrush currents, such as motors or transformer systems, as it tolerates short-term overloads without unnecessary tripping.

Functions and Equipment in Detail

The switch operates as a miniature circuit breaker and is designed for installation in standard distribution enclosures. The Type S tripping characteristic ensures thermal tripping at current values between 3 and 6 times the rated current, with tripping occurring at 6 times the rated current within 1 to 10 seconds. This enables selective protection, minimizing the failure cascade in complex circuits. The 1-pole construction reduces space requirements in the enclosure and is suitable for applications where only one phase needs to be protected.

Technology Explained Simply

The switch uses a combination of thermal and magnetic tripping functions. For prolonged overloads (e.g., 1.13 to 3 times the rated current), the thermal tripping is activated, which is implemented via a bimetal strip. For sudden short circuits (starting at approximately 6 times the rated current), magnetic tripping occurs, reacting within milliseconds. The Type S characteristic extends the thermal tripping time in the range of 3 to 6 times the current, increasing compatibility with installations featuring high inrush currents. The IP20 protection rating safeguards against contact with fingers and solid foreign objects, but is not suitable for damp or dusty environments.

Compatibility and Accessories

The FAZ-S1/1 is designed for use in distribution enclosures with standard modular construction. It is compatible with various Euro-Vario busbars from the EVG-16 series, available in different configurations (e.g., 2- or 3-phase, with or without neutral conductor) and module counts (e.g., 4, 6, 10, 12 modules). These busbars enable flexible and modular installation. Additionally, auxiliary switches such as the FAZ-XAM002 (2-way) or FAZ-XHINW1 (1-way) can be connected for signal transmission or status indication. For special requirements, load current release devices such as the FAZ-XAA-C-110-415VAC are also available, providing additional protection for specific loads.

Installation and Mounting

The switch is installed in standard distribution enclosures, with mounting via a rail. Installation requires no special tools, as the switch is simply inserted into the busbar and locked in place. Wiring is done via the terminals at the connection points, with the maximum permissible cross-section to be observed according to VDE standards and the data sheet. The IP20 protection rating requires installation in enclosed, dry rooms to ensure functionality and safety.

Operational Advantages

The FAZ-S1/1 offers reliable protection with high selectivity, especially in installations with high inrush currents. The Type S characteristic minimizes unnecessary shutdowns during short-term current surges, enhancing operational safety. The compact 1-pole design reduces space requirements in the enclosure, and its use in combination with Euro-Vario busbars enables modular and flexible installation. The IP20 protection rating ensures safe operation in indoor environments where no special environmental conditions are present.
This is an offer of:

Lieske Elektronik e.K.

Reutener Str. 10
79279 Vörstetten

https://industry-electronics.com
Tel. 07666/88499-0
Fax. 07666/88499-111

Diesen Artikel finden Sie unter:
industry-electronics.com/artikel/230701
qrcode für Moeller 278606 Circuit Breaker 1A 1p S-Char