| General |
| Operating voltage | 24 V DC |
| Tripping range | 35 - 70 % US |
| Function | Under voltage coil |
The
undervoltage release NZM2/3-XU24DC from
Eaton is a modular accessory for the NZM circuit breaker series. It ensures the safe disconnection of the breaker when the control voltage drops below a predefined range. This release is specifically designed for operating voltages of 24 V DC and enables immediate disconnection of the NZM circuit breaker or N disconnector as soon as the voltage falls below 35 to 70 % of the rated voltage (US). The function is particularly relevant in installations requiring continuous power supply and helps prevent damage caused by insufficient voltage.
Applications
The undervoltage release is used in industrial installations where safe and reliable disconnection during voltage dips is required. It is especially suitable for systems with emergency stop devices, operated in conjunction with an emergency stop switch. In such installations, the release ensures that the breaker is immediately and without delay disconnected during voltage dips, protecting personnel and machinery. The modular design allows for flexible integration into existing control systems.
Functions and Equipment in Detail
The release operates with an operating voltage of 24 V DC and responds to voltage dips below 35 to 70 % of the rated voltage. Upon reaching this range, the breaker is disconnected immediately. A special safety feature prevents accidental contact with the main contacts of the breaker during switching attempts when the undervoltage release is deactivated. This increases safety during maintenance work and reduces the risk of short circuits or electric shocks.
Technology Explained Simply
The undervoltage release continuously monitors the control voltage. When this voltage falls below the defined threshold, an electromechanical tripping mechanism is activated, immediately disconnecting the breaker. The tripping occurs without delay, which is crucial for critical applications where even short voltage dips could cause damage. The operating voltage of 24 V DC is a standard in industrial electrical engineering, particularly in control and automation systems.
Compatibility and Accessories
The NZM2/3-XU24DC is designed as an optional accessory for the NZM circuit breaker series. It is compatible with various models of the NZM series, including circuit breakers with rated currents such as 100 A, 125 A, 160 A, 200 A, 250 A, 350 A, 600 A, and 630 A. The modular design enables easy mounting and integration into existing control systems. Use with emergency stop switches is specifically intended to extend safety functions.
Mounting and Installation
Mounting is flexible and simple thanks to the modular functional groups. The release is directly integrated into the circuit breaker housing, with electrical connections linked to the control voltage supply. Installation does not require special tools or additional components. The terminal assignment corresponds to the standards of the NZM series, making integration into existing systems straightforward.
Advantages in Operation
Using the undervoltage release increases the safety and reliability of electrical installations. Immediate disconnection during voltage dips protects machines and systems from damage. The deactivation function prevents dangerous contacts during maintenance work. The modular design and easy mounting reduce installation time and simplify maintenance. Compatibility with a wide range of NZM circuit breakers makes the release a universally applicable safety module in industrial installations.