Eaton 236947, EAN: 4015082369477

Moeller 236947 PXK-B13/1N/003-A residual current circuit breaker 30 mA

Installation > Modular devices / equipment installation > RCD

Moeller 236947 PXK-B13/1N/003-A residual current circuit breaker 30 mA

Lieske Part No. 697592
Mfg Part No 236947
EAN-Code 4015082369477
Manufacturer Eaton
Here only 217,00 EUR
258,23 EUR incl. VAT

Further information for Moeller 236947 PXK-B13/1N/003-A residual current circuit breaker 30 mA

Features
Circuit breaker typeMiniature circuit breaker
Breaking capacity10000 A
Number of poles2
International Protection (IP) codeIP20
Pollution degree2
Operational conditions
Operating temperature (T-T)-25 - 40 °C
Power
Rated current13 A
Rated voltage240 V
Weight & dimensions
Depth69.5 mm
The article is a residual current circuit breaker with overload protection (RCBO) of the brand Eaton, type PXK-B13/1N/003-A, designed as a miniature circuit breaker. It combines overload protection with residual current protection and is intended for use in residential and commercial installations. The switch is configured as 1-pole + N, meaning it protects one conductor (phase) and the neutral conductor (N). It is rated for a nominal current of 13 A and trips at a residual current of 30 mA (0.03 A), corresponding to protection class A. The rated switching capacity is 10 kA, according to IEC/EN standards, describing the device’s ability to safely interrupt a short-circuit current. The nominal voltage is 240 V, typical for single-phase networks in Germany and other European countries.

Applications

The switch is designed for use in residential buildings and commercial installations where high safety standards for electrical installations are required. It protects people from dangerous residual currents that may arise from contact with live parts or insulation faults. The combination of overload and residual current protection in a single device reduces the number of required switching devices in the distribution box and simplifies installation. The protection rating IP20 means the device is protected against contact with fingers or similar objects, but not against water or dust — therefore, it is intended for indoor use only.

Functions and Equipment in Detail

The switch features a B characteristic, typical for tripping under overload conditions. This characteristic ensures that the switch does not unnecessarily trip during short-term current surges, such as those occurring during motor or heater startup, but only trips during sustained overloads. The A characteristic for residual current protection means the switch trips at a residual current of 30 mA regardless of the phase position of the current. This is particularly important for protection against electric shocks. The depth of the device is 69.5 mm, which must be considered when planning the dimensions of the distribution box.

Technology Explained Simply

An RCBO (Residual Current Circuit Breaker with Overload Protection) is an integrated switching device that combines overload protection (circuit protection) and residual current protection (RCD protection) in a single housing. In the event of an overload, i.e., when the current exceeds the nominal value of 13 A, the switch trips to protect the wiring from overheating. In the case of a residual current, caused by insulation failure or contact with a live part, the switch also trips as soon as the current difference between phase and neutral reaches 30 mA. The switching capacity of 10 kA describes the maximum current the device can safely interrupt without damage. The operating temperature range of -25 °C to 40 °C allows use in rooms with varying ambient conditions, as long as the temperature remains within this range.

Compatibility and Accessories

The switch is designed for use in standard distribution boxes suitable for 1-pole + N switching devices. It is part of Eaton’s PXK series, known for its reliability and standardization in electrical installations. The IP20 protection rating requires that the device be installed in enclosed distribution boxes that are protected against mechanical impacts and contact.

Mounting and Installation

Installation takes place in a suitable distribution box providing a minimum depth of 69.5 mm. The switch is inserted into the mounting rail and connected to the corresponding conductors (phase and neutral). Installation must comply with applicable VDE and DIN standards, ensuring correct polarity and adherence to the IP20 protection rating. The operating temperature range of -25 °C to 40 °C must be maintained at the installation site to ensure proper functionality.

Advantages in Operation

The combination of overload and residual current protection in a single device reduces the number of switching devices required in the distribution box and simplifies installation. The B characteristic ensures reliable tripping during sustained overloads without unnecessary tripping during short-term current surges. Tripping at 30 mA residual current provides high protection against electric shocks. The 10 kA switching capacity ensures safety during short circuits. The operating temperature range of -25 °C to 40 °C allows use in a wide range of indoor environments, including those with climatic fluctuations.
This is an offer of:

Lieske Elektronik e.K.

Reutener Str. 10
79279 Vörstetten

https://industry-electronics.com
Tel. 07666/88499-0
Fax. 07666/88499-111

Diesen Artikel finden Sie unter:
industry-electronics.com/artikel/697592
qrcode für Moeller 236947 PXK-B13/1N/003-A residual current circuit breaker 30 mA