Eaton 236780, EAN: 4015082367800

Moeller 236780 RCD 4P 63A 30mA Type A

Installation > Modular devices / equipment installation > RCD

Moeller 236780 RCD 4P 63A 30mA Type A

Lieske Part No. 681235
Mfg Part No 236780
EAN-Code 4015082367800
Manufacturer Eaton
Here only 428,05 EUR
509,38 EUR incl. VAT

Further information for Moeller 236780 RCD 4P 63A 30mA Type A

Features
Circuit breaker typeResidual-current device
Breaking capacity10000 A
Number of poles4
International Protection (IP) codeIP20
Pollution degree2
Operational conditions
Operating temperature (T-T)-25 - 40 °C
Power
Rated current63 A
Rated voltage400 V
Weight & dimensions
Depth70.5 mm
The residual current circuit breaker PXF-63/4/003-A from Eaton is a 4-pole circuit breaker designed for use in electrical installations in residential buildings as well as in commercial applications. It is rated for a nominal current of 63 A and protects electrical systems against dangerous fault currents, particularly in cases of indirect contact. The breaker is designed for a rated voltage of 400 V and offers a rated short-circuit withstand capacity of 10 kA, making it suitable for installations with high short-circuit currents. The rated residual current is 0.03 A (30 mA), which is the standard value for protection against electric accidents in residential and office buildings. The circuit breaker conforms to Type A, which also reliably responds to pulsating fault currents, such as those generated by electronic devices or fluorescent lamps.

Residual current circuit breakers are essential in electrical installations to protect people from dangerous touch currents. The PXF-63/4/003-A detects fault currents exceeding 30 mA and disconnects the power supply within milliseconds. This minimizes the risk of electric shock and prevents damage to electrical devices. The 4-pole configuration enables protection of three-phase AC systems with a neutral conductor, which is common in many residential and commercial installations.

Switching capacity and rated short-circuit withstand capacity are critical parameters for the safety and reliability of the device. The switching capacity of 10000 A describes the maximum current the breaker can safely switch without damage. The rated short-circuit withstand capacity of 10 kA ensures that the breaker will not be destroyed in the event of a sudden short circuit in the network, but will safely disconnect the power supply. These values are particularly important in installations with high electrical loads.

The protection class IP20 means that the breaker is protected against contact with fingers and against solid foreign objects with a diameter of at least 12.5 mm. It is not intended for outdoor use or in damp environments, as it is not waterproof. The pollution degree rating of 2 indicates that the breaker is suitable for environments where only minor contamination by solid dust or dirt occurs, such as in typical indoor spaces.

Operating temperature from -25 °C to 40 °C allows the breaker to be used in a wide range of indoor environments, including those with climate control. The depth of 70.5 mm is important for mounting in standard installation enclosures and boxes, as it determines the installation size and space requirement in the enclosure. The installation size corresponds to the standard for modular installation devices, enabling easy integration into existing installations.

The breaker is intended for use in residential and commercial installations where high safety and reliability are required. It is particularly suitable for systems supplying electronic devices, heating systems, kitchen appliances, or lighting systems. The combination of 4-pole configuration, 30 mA residual current protection, and Type A makes it a universally applicable device in electrical installations.

Installation is carried out in standard installation enclosures or boxes designed for modular devices. The installation size and depth are dimensioned so that the breaker can be easily mounted in typical enclosures. No additional mounting accessories are required, as the breaker is standard-equipped with the necessary fastening elements.

In operation, the PXF-63/4/003-A provides reliable disconnection in the event of fault currents, increasing the safety of the installation and its users. The fast response time minimizes the risk of fires or electrical accidents. The mechanical and electrical stability of the device ensures a long service life and low maintenance costs.

Residual current circuit breaker, Type A, IP20, rated current 63 A, rated residual current 30 mA, 4-pole are the key features that define the application range and function of the device. These characteristics meet the requirements of modern electrical installations and ensure safe operation in residential and commercial applications.
This is an offer of:

Lieske Elektronik e.K.

Reutener Str. 10
79279 Vörstetten

https://industry-electronics.com
Tel. 07666/88499-0
Fax. 07666/88499-111

Diesen Artikel finden Sie unter:
industry-electronics.com/artikel/681235
qrcode für Moeller 236780 RCD 4P 63A 30mA Type A