| Features |
| Circuit breaker type | Miniature circuit breaker |
| Breaking capacity | 10000 A |
| Number of poles | 1 |
| International Protection (IP) code | IP20 |
| Pollution degree | 2 |
| Operational conditions |
| Operating temperature (T-T) | -25 - 55 °C |
| Power |
| Rated current | 32 A |
| Rated voltage | 230 V |
| Weight & dimensions |
| Depth | 70.5 mm |
The PXL-B32/1 circuit breaker from Eaton is a miniature circuit breaker designed for use in residential and commercial installations. It is single-pole and features a Type B tripping characteristic, suitable for protecting consumers with moderate inrush currents. With a rated current of 32 A and a nominal voltage of 230 V, it covers typical applications in electrical installations. The switching capacity is 10000 A, corresponding to the rated switching capacity according to IEC/EN 60898-1, ensuring safe disconnection under short-circuit conditions.
Circuit breaker devices provide protection in electrical systems by automatically disconnecting the circuit in case of overload or short-circuit. The PXL-B32/1 is specifically designed for use in residential buildings and commercial facilities where reliable and safe power supply is required. The Type B tripping characteristic ensures that the breaker trips within a defined time when current exceeds 32 A but remains below 100 A, preventing damage to the installation or connected devices.
Miniature circuit breaker units are characterised by compact dimensions and high functionality. The PXL-B32/1 has a depth of 70.5 mm, making it suitable for installation in standard installation enclosures. The protection rating IP20 means the breaker is protected against contact with fingers or similar objects, but not against dust or water. It is therefore intended for indoor use where no special environmental conditions such as humidity or contamination prevail.
Switching capacity is a critical parameter for safety during short-circuit events. With 10000 A (10 kA), the PXL-B32/1 provides sufficient switching capacity for typical applications in residential buildings and small commercial facilities. The standard IEC/EN 60898-1, which defines the switching capacity, ensures that the breaker operates reliably under defined conditions and guarantees the safety of the installation.
Operating temperature range of -25 °C to 55 °C allows the breaker to be used in a wide range of indoor environments, including those with seasonal temperature fluctuations. The pollution degree rating 2 refers to the environmental conditions under which the breaker may be operated — in this case, environments with low pollution, as commonly found in residential and office buildings.
Compatibility and accessories: The breaker is designed for installation in standard installation enclosures. As suitable accessories, the Euro-Vario busbar EVG-16/3PHAS/12MODUL (article number 291472) is offered, enabling secure and orderly connection of breakers within an enclosure. This busbar is rated for a nominal current of 100 A and supports the installation of multiple breakers in a modular system.
Mounting and installation typically take place in an installation box or enclosure, with the mounting width and depth of the device taken into account. The mounting width corresponds to the standard for modular devices, allowing easy integration into existing installations. Mounting is achieved via mechanical locking into the enclosure, with electrical connections made through the terminals on the device.
Operational advantages include reliability and a high protection standard. The breaker responds precisely to overloads and short-circuits, protecting the electrical installation from damage. The compact design and standardisation according to IEC/EN 60898-1 simplify planning and installation. The Type B tripping characteristic is particularly suitable for applications involving electrical devices that exhibit a temporary current surge at start-up, such as motors or heaters.