| General |
| Rated control voltage | 208-240 V AC 50/60 Hz |
| Operating range x factor | 0,7 - 1,1 |
| Max. holding current | 0,034 A |
| Max. pull-in current (35 ms) | 3,01 A |
| Max. continuous power | 9 VA/W |
| Max. pull-in power (35 ms) | 500 VA/W |
| Maximum switching frequency per minute | 3 |
| Total switching time at US = 100 % | 30 ms (IZMX16, INX16) |
The article
Eaton +IZMX-ST230AD-1 is an
operating current trip unit for IZMX series circuit breakers. It serves as additional equipment for electrical control and switching operations in the operation of circuit breakers, particularly in industrial installations. The trip unit enables remote control of the switch via an external control voltage and is designed for operating voltages in the range of 208 to 240 V AC (50/60 Hz) as well as 208 to 250 V DC. It is designed to be combined with an undervoltage trip unit or a second voltage trip unit, enabling flexible and secure control in complex switching installations.
Applications
The operating current trip unit is used in industrial electrical installations where remote switching functionality is required, for example in production plants, power distribution systems, or for controlling motors and machines. It is particularly suitable for applications requiring high switching accuracy and reliability. The maximum switching frequency is 3 operations per minute, limited due to the high inrush current of 3.01 A (for 35 ms). The total switching time of the circuit breaker at 100 % control voltage is 30 ms (for IZMX16 and INX16) or 35 ms (for IZMX40). The overall switching frequency of the circuit breaker is 60 operations per hour.
Functions and Equipment in Detail
The trip unit is designed for a
rated control voltage of 208–240 V AC (50/60 Hz) and 208–250 V DC. The operating range of the control voltage is between 0.7 and 1.1 times the nominal voltage, ensuring stable operation even with voltage fluctuations. The maximum holding current is 0.034 A, while the maximum inrush current (for 35 ms) is 3.01 A. The maximum continuous power is 9 VA/W, and the maximum inrush power (for 35 ms) is 500 VA/W. These values are relevant for the safe and reliable operation of the trip unit under high loads and short switching operations.
Technology Explained Simply
The operating current trip unit works via electrical control, actuating the switch through a magnetic drive. When the control voltage is applied, the trip unit is activated and performs the switching operation. The limitation of switching frequency to 3/min results from the high inrush current, which flows briefly and is intended to avoid thermal stress. The use of both AC and DC voltages enables flexible integration into different control systems. The switching time of 30 to 35 ms at 100 % control voltage ensures a fast response, which is important for time-critical applications.
Compatibility and Accessories
The trip unit can be combined with various accessories to extend functionality. These include, for example, undervoltage trip units such as the
EATON+IZMX-UVR24DC-1 (24 VDC) or
IZMX-UVR24DC-1, closing magnets such as the
EATON+IZMX-SR230AD-1 (220–240 V AC/DC) or
IZMX-SR230AD-1, and signaling switches such as the
EATON+IZMX-LCS-1 (ready to close, 1W) or
EATON+IZMX-AS22-1 (ON-OFF, 2-pole). Motor drives such as the
EATON+IZMX-M40-230AD-1 (208–240 VAC/DC) or
IZMX-M40-230AD-1 can also be integrated. Control wiring connectors such as the
IZMX-SEC-TB12-F-1 (20 pcs, fixed installation) or
IZMX-SEC-KIT-W16-1 (30 pcs, fixed installation) ensure secure connection of control lines.
Mounting and Installation
Mounting is done directly on the IZMX series circuit breaker. Electrical connections are made via the designated control lines, ensuring compliance with voltage specifications (208–240 V AC/DC). Installation requires no special tools or additional components, as the trip unit is designed as standard accessory for IZMX circuit breakers. Connection to other control or signaling systems is made via the corresponding connection points.
Advantages in Operation
The use of the operating current trip unit enables remote and automated switching functionality, increasing operational safety and simplifying maintenance. The combinability with additional trip units and signaling switches offers high flexibility in switching design. The specific technical data, such as the limited switching frequency and short switching times, are tailored to the requirements of industrial installations to ensure reliable and low-maintenance operation. Compatibility with various accessories expands application possibilities and enables customized solutions for different applications.