| General |
| Degree of protection | RCBO |
| Number of poles | 3 polar + N |
| Rated current | 13 A |
| Rated fault current | 0,03 A |
| LS characteristic | C |
| Rated switching capacity | 6 kA |
| Standards | IEC/EN 60947-2, IEC/EN 61009 |
| Application range | residential area, commercial applications |
The product is a residual current circuit breaker with overload protection, also known as an RCBO (Residual Current Breaker with Overload protection), manufactured by Eaton under the type designation mRB6-13/3N/C/003-A. It is designed for use in residential buildings as well as in commercial installations where reliable electrical protection is required. The device protects electrical consumers and persons from dangerous fault currents as well as from overloads in the circuit. It features a 3-pole configuration with neutral conductor (3p+N) and is rated for a nominal current of 13 A.
Applications
This circuit breaker is intended for use in electrical installations in residential construction and commercial facilities. It is particularly suitable for protective circuits that must safeguard persons from dangerous touch currents, for example in bathrooms, kitchens, or outdoor installations. The combination of residual current and overload protection in a single device reduces the number of required switching devices and simplifies installation.
Functions and Features in Detail
The device automatically trips at a fault current of 30 mA (0.03 A) to prevent electric shock. The rating is according to characteristic C, meaning the breaker trips within seconds at a current of 5 to 10 times the nominal current (i.e., 65 to 130 A). This is typical for applications with motor loads or devices that generate high inrush currents during startup. The switching function is operated via a mechanical lever that indicates the On" or "Off state.
Technology Explained Simply
The circuit breaker combines two protective functions: residual current protection (FI) and overload protection (LS). The residual current protection responds to unintended currents flowing through the protective conductor, for example, due to insulation failure. The overload protection safeguards the wiring against thermal overload caused by excessive current load. The switching capacity is 6 kA, measured according to standards IEC/EN 60947-2 and IEC/EN 61009. This means the device can safely trip even under high short-circuit currents without being damaged.
Compatibility and Accessories
The switch is designed for installation in standard installation switchboards designed for modular devices. It is compatible with other devices in the mRB6 series from Eaton, allowing for a uniform switchboard configuration. Precise installation is carried out in a suitable enclosure or distribution console.
Installation and Mounting
Mounting is performed in a suitable enclosure or distribution console designed for modular devices. The switch is inserted into the designated rail and locked in place. Installation must comply with applicable regulations and standards, particularly VDE 0100 and DIN VDE 0100-410.
Operational Advantages
The combination of residual current and overload protection in a single device reduces the number of required switching devices and simplifies planning and installation. The clear indication of the switching state (On/Off) facilitates maintenance and fault diagnosis. The high switching capacity of 6 kA ensures safe tripping even under high short-circuit currents.