Eaton 110314, EAN: 4015081098620

Moeller 110314 PN3-400-BT load isolator 3p 400A

Industrial Material > Industrial relays and contactors > Switching units / measuring, control relay

Moeller 110314 PN3-400-BT load isolator 3p 400A

Lieske Part No. 390463
Mfg Part No 110314
EAN-Code 4015081098620
Manufacturer Eaton
Here only 1.311,81 EUR
1.561,05 EUR incl. VAT

Further information for Moeller 110314 PN3-400-BT load isolator 3p 400A

General
ManufacturerEaton
Number of poles3
Rated current400 A
Separator propertiesIEC/EN 60947-3, VDE 0660
Compliance with standardsIEC/EN 60204, VDE 0113, VDE 0160 Part 100
Application rangeearthed IT networks, industrial distribution systems
Positive driveYes
The PN3-400-BT disconnect switch from Eaton is an industrial disconnect switch designed for use in distribution systems. It is intended for operation in 3-pole installations and offers a rated current of 400 amperes. The device provides safe disconnection of electrical systems and ensures insulation properties even in earthed IT networks. The construction allows for flexible integration into various distribution systems, with mounting adaptable via various accessories such as connection terminals, bridge kits, or rotary handles for door couplings. The disconnect switch is not designed for remote control functions, but is intended for manual operation.

Disconnecting properties and compliance with standards
The PN3-400-BT meets disconnecting requirements according to IEC/EN 60947-3 and VDE 0660. These standards define requirements for disconnecting and switching devices, particularly regarding safe electrical disconnection and insulation values. Compliance with these standards ensures the switch can be safely used even in hazardous areas of installations. Additionally, the main switch is equipped with a mandatory drive, which increases operational safety and ensures compliance with regulations according to IEC/EN 60204 and VDE 0113. The busbar cover meets the requirements of VDE 0160 Part 100, enhancing safety during installation and maintenance.

Applications
The disconnect switch is intended for use in industrial and commercial electrical installations, particularly in distribution systems where safe and visible disconnection of power supply is required. It is commonly used in machine controls, drive systems, or distribution boxes, where isolation of circuits is necessary for maintenance work or during faults. Its use in earthed IT networks also makes it suitable for special applications in medical technology or critical infrastructures, where high safety standards are required.

Functions and equipment in detail
The PN3-400-BT is designed as a 3-pole disconnect switch, making it suitable for three-phase AC systems. The rated current of 400 A allows use in medium to high-power installations. The construction permits mounting in various distribution systems, with adaptation achieved through accessories such as connection terminals, bridge kits, or rotary handles for door couplings. These components are available optionally and allow individual adaptation to specific installation conditions. Mounting is performed in standard distribution boxes or enclosures, with the busbar cover enhancing safety during handling.

Compatibility and accessories
Various accessories are available for the PN3-400-BT disconnect switch, supporting installation and operation. These include connection covers such as NZM3-4-XKSFA, cable lug covers such as NZM3-4-XKSAE, and various rotary handles, including lockable models such as NZM3-XTVDV-0 or NZM3-XDVR. Additional components include spacers (NZM3-XAB), frame terminals (NZM3-4-XKCU), tunnel terminals (NZM3-4-XKA1), and kits for main switches (e.g., NZM3-XSR-L). These accessories enable flexible and safe mounting in different environments and requirements.

Mounting and installation
Mounting of the PN3-400-BT is performed in standard distribution boxes or enclosures. The use of connection terminals and bridge kits facilitates integration into existing systems. Rotary handles for door couplings, especially lockable variants, enable secure operation and prevent unintended actuation. The busbar cover provides additional protection and complies with regulations according to VDE 0160 Part 100. Installation is carried out by qualified personnel in accordance with applicable safety regulations.

Operational advantages
The PN3-400-BT provides reliable and safe disconnection of electrical systems. Compliance with international standards such as IEC/EN 60947-3 and VDE 0660 ensures safety requirements are met. The use of a mandatory drive increases operational safety and prevents unintended switching operations. The modular equipment with various accessories allows flexible adaptation to different requirements. Mounting is standardized and performed in common distribution systems, making integration into existing installations simple and safe.

Technical explanation in simple terms
A disconnect switch like the PN3-400-BT is used to completely disconnect an electrical circuit to create a safe working environment. The 3-pole design means all three phases of a three-phase AC system are disconnected simultaneously. The rated current of 400 A indicates the maximum current the switch can carry continuously without overheating or damage. Standards IEC/EN 60947-3 and VDE 0660 define requirements for insulation values and mechanical strength to ensure the switch operates safely under load. The mandatory drive ensures the switch can only be held in a defined position (on or off), enhancing operational safety.

Additional information
The disconnect switch is not designed for remote control functions, but for manual operation. The use of accessories such as rotary handles, covers, or terminals is optional and serves to adapt to specific requirements. The busbar cover is an integrated component that enhances safety during installation and maintenance. Compliance with standards IEC/EN 60204, VDE 0113, IEC/EN 60947-3, VDE 0660, and VDE 0160 Part 100 ensures conformity with applicable safety regulations.

Important standards and regulations
Compliance with standards IEC/EN 60947-3, VDE 0660, IEC/EN 60204, VDE 0113, and VDE 0160 Part 100 is essential for the safety and functionality of the disconnect switch. These standards define requirements for insulation values, mechanical strength, operational safety, and mounting conditions. Compliance with these standards ensures the switch can be safely used in industrial and commercial installations.

Important standards and regulations
Compliance with standards IEC/EN 60947-3, VDE 0660, IEC/EN 60204, VDE 0113, and VDE 0160 Part 100 is essential for the safety and functionality of the disconnect switch. These standards define requirements for insulation values, mechanical strength, operational safety, and mounting conditions. Compliance with these standards ensures the switch can be safely used in industrial and commercial installations.
This is an offer of:

Lieske Elektronik e.K.

Reutener Str. 10
79279 Vörstetten

https://industry-electronics.com
Tel. 07666/88499-0
Fax. 07666/88499-111

Diesen Artikel finden Sie unter:
industry-electronics.com/artikel/390463
qrcode für Moeller 110314 PN3-400-BT load isolator 3p 400A