Moeller 073129 U-PKZ0(24V50HZ) undervoltage release undelayed

Industrial Material > Control devices / Pilot devices > Breakers and disconnectors

Moeller 073129 U-PKZ0(24V50HZ) undervoltage release undelayed

Lieske Part No. 141956
Mfg Part No 073129
EAN-Code 4015080731290
Manufacturer Eaton
Here only 94,56 EUR
112,53 EUR incl. VAT

Further information for Moeller 073129 U-PKZ0(24V50HZ) undervoltage release undelayed

General
ModelUndelayed
Construction sizePKZ(M)0
Operating voltage24 V
Frequency50 Hz
The undervoltage release U-PKZ0(24V50HZ) from Eaton is a specific accessory for circuit breakers of size PKZ(M)0. It enables automatic disconnection of the switch as soon as the operating voltage drops below a predefined threshold, thereby protecting electrical devices and systems from damage caused by insufficient voltage. The release operates without delay, meaning it reacts immediately as soon as the voltage falls below the minimum value, without any time delay. This is particularly important in systems with critical loads, where interruption of power supply must be prevented immediately.

Applications

The undervoltage release is used in industrial and commercial installations where constant and sufficient voltage is required for the operation of electrical devices. It is suitable for applications in manufacturing technology, building automation, pump and ventilation systems, and other systems where interruption of power supply could lead to functional failures or damage. The device is used exclusively in conjunction with circuit breakers of size PKZ(M)0, and the exact mounting and integration into the existing switching device must be carried out by a qualified specialist.

Functions and Equipment in Detail

The release is designed for an operating voltage of 24 V and operates at a frequency of 50 Hz. It is designed for immediate operation, meaning it has no time delay and reacts instantly when undervoltage occurs. This ensures fast and reliable disconnection as soon as the voltage drops below the required minimum. The function requires no additional settings or configurations — the release is immediately operational once mounted in the circuit breaker. The 24 V operating voltage is typical for control and safety circuits in industrial installations, where even minor voltage fluctuations are sufficient to trigger disconnection.

Technology Explained Simply

An undervoltage release monitors the voltage in the circuit in which it is installed. When the voltage drops below a certain threshold — in this case for 24 V — the release is activated and causes the circuit breaker to disconnect. The immediate operation means no time delay is built in; the reaction occurs instantly. This is particularly important in installations where even a brief interruption in voltage can lead to system failure. The technology is based on electromagnetic principles, where voltage fluctuations affect the magnetic force responsible for holding the switch in the on position. When the voltage drops, the force is no longer sufficient to keep the switch engaged, causing it to automatically disconnect.

Compatibility and Accessories

The undervoltage release U-PKZ0(24V50HZ) is specifically designed for circuit breakers of size PKZ(M)0. It is not suitable for other sizes or switch types. Installation is carried out directly within the circuit breaker, with the exact mounting technique corresponding to the specific switch model. No additional components or accessories are required specifically for this release — integration occurs exclusively within the existing switching device. Use in combination with other safety functions such as overvoltage protection or thermal disconnection is possible, provided the switching devices support such features.

Mounting and Installation

Installation must be carried out by qualified personnel and requires disassembling the existing circuit breaker to install the undervoltage release. The exact procedure depends on the specific switch model and the technical specifications provided by the manufacturer. It is essential to ensure the release is correctly installed in the switching device to guarantee reliable operation. Installation must be performed in a de-energized circuit to avoid any electrical hazards. After installation, a functional test is required to verify the correct operation of the release.

Advantages in Operation

Using the undervoltage release provides an additional safety level in electrical installations. It prevents devices from operating under insufficient voltage, which could lead to malfunctions, overheating, or damage. The immediate response ensures rapid disconnection as soon as the voltage drops critically. This is particularly important in installations where even a short interruption in power supply can lead to system failure. Integration into existing circuit breakers of size PKZ(M)0 requires no additional components, simplifying installation and enhancing operational safety.