| General |
| Contact type | 2 Ö |
| Connection type | Screw terminals |
| Compatibility | motor protection switch size PKZ(M)0 |
| Function | trip indicator |
The article AGM2-01-PKZ0 from Eaton is a tripped indicator designed specifically for motor protection circuit breakers of size PKZ(M)0. It serves as an auxiliary contact to indicate the state of the circuit breaker—particularly the tripped condition—in an electrical circuit diagram or control unit. The indicator features two normally open contacts (2 O) and is equipped with screw terminals, enabling simple and secure connection to wiring. It is mounted on the right side of the circuit breaker and is suitable for use in industrial installations and electrical distributions where visual or electrical feedback on the operating state is required.
Applications
The tripped indicator AGM2-01-PKZ0 is used in installations where monitoring the state of the circuit breaker is important, for example in pump control systems, fan installations, or other motor-driven systems. It allows the tripping event of the motor protection circuit breaker to be detected externally, for instance via a warning light, alarm system, or control logic. Its use in combination with circuit breakers of size PKZ(M)0 is intended, with mounting directly on the device. The application is in industrial environments where reliable state indication is necessary.
Functions and Equipment in Detail
The indicator features two normally open contacts (2 O), which close when the circuit breaker trips. These contacts can be used in circuits to activate, for example, a warning indicator or influence control. The screw terminals provide a mechanically stable and electrically secure connection. Mounting is on the right side of the circuit breaker, with mechanical connection via the integrated holder. The connection method is designed for use in industrial switchgear, with terminals suitable for cable connections.
Technology Explained Simply
The tripped indicator operates mechanically: when the motor protection circuit breaker trips, the indicator is activated via a mechanical connection, causing the contacts to close. The two normally open contacts (2 O) are designed to be open in normal operating position and close when tripped. This enables integration into external circuits, for example to trigger a warning signal. The screw terminals ensure a secure connection that remains stable even under vibration or mechanical stress. The construction is designed for industrial environments, with focus on mechanical durability and reliability.
Compatibility and Accessories
The tripped indicator AGM2-01-PKZ0 is specifically designed for motor protection circuit breakers of size PKZ(M)0. It can be combined with various models of this size, such as types PKZM4-16, PKZM4-25, PKZM4-32, PKZM4-40, PKZM4-50, PKZM4-58, PKZM4-63, as well as corresponding variants with additional designations such as /AK or -CB. Mounting is directly on the circuit breaker, with mechanical connection via the integrated holder. Use in combination with other accessories such as support rails (e.g. PKZM0-XMR54) is possible, provided the mounting geometry is compatible.
Mounting and Installation
Mounting of the tripped indicator is on the right side of the motor protection circuit breaker of size PKZ(M)0. Mechanical fastening is via the integrated holder, which is attached to the circuit breaker. Electrical connection is via the screw terminals, intended for connection wires. Installation requires no additional tools or components, as the indicator is mounted directly on the circuit breaker. Wiring is done according to circuit diagram specifications, with the two normally open contacts (2 O) integrated into the desired circuit.
Advantages in Operation
Using the tripped indicator AGM2-01-PKZ0 enables external state indication of the motor protection circuit breaker, simplifying fault diagnosis and maintenance. The mechanical connection ensures reliable signal transmission, and the screw terminals guarantee a stable electrical connection. Integration into existing circuits is straightforward, as the contacts can be directly connected to control or warning systems. Use in industrial installations increases transparency of the operating state and supports process safety.