| General |
| Number of contacts | 2 S |
| Connection type | Screw terminals |
| Compatibility | motor protection switch size PKZ(M)0 |
The AGM2-10-PKZ0 product from Eaton is a tripped indicator, specifically designed for motor protection circuit breakers of size PKZ(M)0. It serves as a visual signal to indicate the status of a protection circuit breaker, particularly when it has tripped. The indicator is equipped with screw terminals, enabling a secure and easy electrical connection. It is used in industrial and commercial installations where clear status indication is important for the operation and maintenance of electrical drives.
Applications
The tripped indicator AGM2-10-PKZ0 is intended for use in electrical installations where motor protection circuit breakers of size PKZ(M)0 are installed. It is typically used in industrial electrical engineering, manufacturing technology, and installations with electrical drives to visually monitor the operating status of the protection circuit breaker. The indication is provided via two switch contacts (2 S), which signal the tripped state. This supports quick fault detection and maintenance of the installation.
Functions and Equipment in Detail
The indicator features two switch contacts (2 S), which close an electrical contact when the motor protection circuit breaker trips. This enables the activation of external signals, such as a warning light or alarm, to inform the operator of the status. The screw terminals ensure a robust and reliable connection that remains stable even under industrial conditions. Mounting is directly on the circuit breaker, with positioning on the right side possible, as specified in the technical description.
Technology Explained Simply
The tripped indicator operates as a mechanical auxiliary switch, mechanically coupled to the motor protection circuit breaker. When the circuit breaker trips, the indicator is activated by the movement of the switch and closes the two contacts. This function is independent of the electrical voltage in the circuit breaker and is based on mechanical movement. The screw terminals allow for an easy and secure connection to external controls or indicators. The designation 2 S refers to the number of switch contacts used for signal transmission.
Compatibility and Accessories
The indicator is specifically designed for motor protection circuit breakers of size PKZ(M)0. It is compatible with various models of this size, such as types PKZM0-10/AK, PKZM0-16/AK, PKZM0-25/AK, and others listed in the compatible accessories. Mounting is directly on the circuit breaker, with positioning on the right side possible. Use with other sizes or switch types is not intended and not recommended.
Mounting and Installation
The tripped indicator is mounted directly on the motor protection circuit breaker of size PKZ(M)0. It is attached to the right side of the switch, ensuring the mechanical connection to the switch activates the indicator when the switch moves. The electrical connection is made via the screw terminals, which ensure a secure and durable connection. No additional tools or components are required to install the indicator. Installation typically occurs during the mounting or maintenance of the motor protection circuit breaker.
Advantages in Operation
The use of the tripped indicator AGM2-10-PKZ0 enables quick and visual recognition of whether a motor protection circuit breaker has tripped. This reduces fault diagnosis time and supports installation maintenance. The screw terminals ensure a reliable electrical connection that remains stable even under industrial conditions. The clear signaling via two contacts (2 S) allows integration into existing control and monitoring systems without requiring additional components. The mechanical coupling with the circuit breaker ensures an independent and reliable function that does not depend on electrical power supply.