The article 019095 from Eaton, type P1DILEM, is a parallel connector for power contactors of the DILEEM, DILEM12 and DILEM series. It is used to increase the current rating of contactors in industrial applications, particularly in systems with higher current requirements. The parallel connector consists of two 4-pole main current terminals, which are installed in parallel with the main current path of the contactor to increase current capacity. The 4th pole is breakable, allowing flexible adaptation to 3- or 4-pole circuits.
Applications
The parallel connector is used in industrial systems where the current rating of a contactor must exceed standard values. It is specifically designed for the DILEEM, DILEM12 and DILEM series, which are widely used in manufacturing, machine building and drive technology. It is employed in control panels where high current levels are required for controlling motors or other electrical loads.
Functions and Features in Detail
The parallel connector increases the AC-1 current rating of the open contactor by a factor of 2.5. This means the current capacity that the contactor can handle during operation is significantly increased, without exceeding the mechanical or thermal limits of the contactor. The terminals are 4-pole, with the 4th pole being breakable, allowing the connector to be used in both 3-pole and 4-pole circuits. The thermal current rating (Ith) is 60 A for 4-pole configuration and 50 A for 3-pole configuration.
Technical Explanation
The parallel connection of the current terminals causes the current to flow through two parallel paths, reducing the current density in each individual path. This reduces the thermal load on the contacts and allows for higher overall current capacity. The increase in current rating by a factor of 2.5 is a direct result of this parallel current path. The terminals are designed to be directly installed into the main current path of the contactor, without requiring additional components or modifications to the contactor itself.
Compatibility and Accessories
The parallel connector is specifically developed for the contactor series DILEEM, DILEM12 and DILEM. It is compatible with various models within these series, including power contactors with rated voltages such as 230 V/50 Hz, 240 V/60 Hz, 110 V/50 Hz, 120 V/60 Hz, and 24 V DC. The mentioned contactor models cover power ratings from 3 kW to 4 kW at 400 V AC. The connector is used in combination with the specified contactors to increase their current rating.
Installation and Mounting
Installation is performed by mounting the two main current terminals into the main current path of the contactor. The terminals are connected to the corresponding connection points, with the 4-pole configuration being standard. If required, the 4th pole can be broken off to enable 3-pole applications. Installation does not require special tools or additional components; the terminals can be directly integrated into the existing control panel.
Operational Advantages
Using the parallel connector increases the current rating of the contactor, enabling its use in systems with higher current demands. This reduces the need to switch to larger contactor models, which are often more expensive and larger in size. The 2.5-fold increase in current rating leads to more efficient use of existing contactors and extends their service life by reducing thermal stress. The flexible 3- or 4-pole usage enhances adaptability to various circuit configurations.