Further information for Eaton ELP1600IEC UPS 1200 VA

Battery
Battery technologySealed Lead Acid (VRLA)
Typical backup time at half load9 min
Hot-swap batteryNo
Automatic battery testYes
Cold startYes
Design
Form factorTower
Rack capacity2U
Product colourBlack
Display typeLCD
LED indicatorsYes
Features
UPS topologyLine-Interactive
Output power capacity1.6 kVA
Output power1000 W
Input operation voltage (min)150 V
Input operation voltage (max)285 V
Input frequency50/60 Hz
Output operation voltage (min)220 V
Output operation voltage (max)240 V
Output frequency50 Hz
Surge protection featuresFax, Modem, Network, Telephone
Emergency Power Off (EPO)Yes
Surge protectionYes
Logistics data
Harmonized System (HS) code85078000
Other features
Nominal input voltage230 V
Ports & interfaces
AC outlet typesC13 coupler
Power plugC14 coupler
AC outlets quantity8 AC outlet(s)
USB 2.0 ports quantity1
Modem (RJ-11) ports1
Ethernet LAN (RJ-45) ports1
Safety regulation & standards
SafetyIEC/EN 62040-1, IEC/EN 62040 -2, CB, CE
Weight & dimensions
Width82 mm
Depth390 mm
Height275 mm
Weight11.3 kg
The Eaton Power Quality ELP1600IEC is a line-interactive uninterruptible power supply (UPS) with an output capacity of 1.6 kVA and an output power of 1000 W. It is designed for professional use, particularly for protecting small servers and workstations with demanding applications. The UPS provides stable power protection against voltage fluctuations and power outages and is suitable for use in office environments as well as IT infrastructures. The technology is based on a line-interactive topology, which stabilizes the output voltage using a booster and fader, ensuring continuous power supply. The nominal input voltage is 230 V, with an operating input voltage range between 150 V and 285 V, allowing high tolerance to voltage fluctuations. The output voltage ranges from 220 V to 240 V, and the output frequency is 50 Hz.

Applications

The ELP1600IEC is suitable for use in offices, IT centers, and small server rooms where reliable power supply for critical devices is required. It protects workstations, small servers, network devices, and peripherals against sudden power failures, overvoltages, and voltage fluctuations. The integrated ASR technology (Advanced Surge Reduction) provides specific surge protection for telephone, fax, modem, and DSL connections, enhancing connection reliability for networks and communication devices.

Features and Equipment in Detail

The UPS features an LCD display showing real-time status information and measurements, including current voltage, battery charge level, and operating mode. This enables easy monitoring of the device during operation. The connections include eight AC outlets, four of which are equipped with battery backup and surge protection and are intended for critical devices. The remaining four outlets offer only surge protection and are suitable for peripheral devices. Additionally, a USB 2.0 port is integrated, enabling communication with a computer for controlling and monitoring the UPS. An RJ-11 port for modem/telephone and an RJ-45 Ethernet port complete the interfaces.

Technology Explained Simply

The line-interactive technology operates with a static inverter that activates only during a power outage. In normal operation, the power is cleaned and stabilized via a transformer, increasing efficiency. The integrated EcoControl function enables energy savings of up to 20% by deactivating power supply to non-critical devices when the mains voltage is sufficient. The UPS features an automatic battery test that regularly checks the battery function to ensure reliable backup power. The cold start capability allows the UPS to operate even without a mains connection, which is useful during installation or in emergencies. The typical backup time at half load is 9 minutes, sufficient to safely shut down critical systems.

Compatibility and Accessories

The ELP1600IEC is designed in a tower configuration and can optionally be mounted in a 2U rack. For rack mounting, the ELRACK Ellipse Rack Kit accessory is available, enabling secure and orderly installation. For wall mounting, the ELWALL Ellipse ECO wall-mount kit is available. The UPS is equipped with sealed lead-acid batteries (VRLA), designed for long service life and low maintenance. The safety standards IEC/EN 62040-1 and IEC/EN 62040-2, as well as the certifications CB and CE, are complied with, confirming conformity with European and international standards.

Installation and Mounting

Installation is carried out according to the instructions in the included user manual. The UPS can be set up as a tower unit or integrated into a 19-inch rack. Rack mounting requires the ELRACK accessory, ensuring secure fastening. The connections are clearly labeled, and cabling is done via C13 and C14 connectors.

Operational Advantages

The ELP1600IEC provides reliable power supply with low energy consumption in normal operation. The integrated EcoControl function reduces power consumption and lowers operating costs. The LCD display and USB interface enable easy monitoring and control. The ASR technology protects sensitive communication devices from surges. The hot-swap function is not available, so battery replacement can only be performed when the device is powered off. The UPS is designed for indoor use and does not offer a specific protection class for outdoor environments. The product color is black, and the design is slim and compact, minimizing space requirements. LED indicators support visual status display.

Safety and Standards

The UPS complies with safety standards IEC/EN 62040-1 and IEC/EN 62040-2, which apply to the safety and reliability of UPS systems. The certifications CB and CE confirm conformity with European and international requirements. The battery must be replaced by qualified personnel, as incorrect polarity connection can damage the UPS. The battery life is reduced by 50% if the operating temperature exceeds 25 °C, indicating the need for optimal cooling and temperature control at the installation site. Battery disposal must comply with applicable regulations.