Draka Comteq A-2YF(L)2Y 6x2x0,8 Telephone Cable

Cables > Underground cables > Telecommunications underground cable

Draka Comteq A-2YF(L)2Y 6x2x0,8 Telephone Cable

Lieske Part No. 419843
Mfg Part No
EAN-Code
Manufacturer Draka Comteq
Here only 3,03 EUR
3,61 EUR incl. VAT

Further information for Draka Comteq A-2YF(L)2Y 6x2x0,8 Telephone Cable

General
Nominal voltage225 V
Test voltage2000 V
Loop resistance73,2 Ohm/km
Current carrying capacity5,1 A
Operating capacity55 nF/km
Insulation resistance5 GOhm x km
Capacitive couplings K3 (800 Hz, 300 m)300 pF/400 pF
Cable attenuation (800 Hz)0,78 dB/km
Installation temperature range-20 °C - +50 °C
Temperature range after installation-30 °C - +70 °C
Bending radius7.5 x cable diameter
Conductor diameter0,8 mm
Wire insulationPE
SheathAluminium tape shield with plastic coating and PE sheath
Sheath markingconsecutive telephone handsets and meter marking white
Stranding4 cores to star quad, 5 star quads to basic bundle, 5 or 10 basic bundles to main bundle
FillingPetrolatum
ApplicationConnection cables in local networks and PBX installations, underground installation, cable channels, conduits
NormSt.III Bd.VDE0816
Core windingYes
The cable A-2YF(L)2Y 6 X 2 X 0,8 from Draka Comteq is a telecommunications earth cable specifically designed for installation in soil, cable ducts, and pipes. It serves as a connection cable in local networks and private branch exchange systems and is used for transmitting voice signals and other telecommunications information. The cable is designed for use in telecommunications infrastructure, where reliable and durable signal transmission over long distances is required.

Applications
This cable is intended for use in fixed telephony and signal transmission systems. It is particularly suitable for underground installation in urban and rural networks, where it functions as a connecting element between switching centers and end devices. Installation takes place in cable ducts, pipes, or directly in the ground, with the cable's construction providing protection against mechanical stress and environmental influences such as moisture or temperature fluctuations.

Functions and Equipment in Detail
The cable consists of single-strand, bare copper conductors with a diameter of 0.8 mm. Each conductor is insulated with PE (polyethylene), ensuring high electrical insulation and chemical resistance. The conductors are marked with black rings to enable easy identification and assignment within the network. The cabling is arranged in a star quad system: four conductors form a star quad, five star quads form a basic bundle, and five or ten basic bundles form a main bundle. These bundles are twisted into the cable core, with petrolatum filling and core wrapping enhancing mechanical stability and protection against moisture.

Technology Explained Simply
The sheath consists of a 0.2 mm thick aluminum tape, coated on both sides with plastic and welded to a black PE outer sheath. This sheath protects the cable against external influences such as moisture, mechanical damage, and electromagnetic interference. The sheath is marked with continuous white markings indicating the telephone handset and meter count, which is helpful during installation and maintenance. The rated voltage is 225 V, and the test voltage is 2000 V, highlighting the cable's electrical safety and load capacity. The loop resistance is 73.2 Ohm/km, ensuring efficient signal transmission. The current-carrying capacity is 5.1 A, indicating the maximum current the cable can safely transmit. The operating capacitance is 55 nF/km, and the insulation resistance is 5 GOhm x km, demonstrating high insulation quality. The capacitive couplings K3 (800 Hz, 300 m) are 300 pF/400 pF, and the line attenuation is approximately 0.78 dB/km at 800 Hz, indicating low signal loss.

Compatibility and Accessories
The cable is designed for use in existing telecommunications and telecommunication networks and is compatible with standard connection and installation techniques. It can be connected to other cables of the same type or compatible systems, with the connection method meeting the requirements of the specific installation. Installation is carried out in accordance with standards and regulations for telecommunications cables, particularly according to St.III Bd.VDE0816.

Installation and Mounting
Installation is performed within specified temperature ranges: during installation between -20 °C and +50 °C, and after installation between -30 °C and +70 °C. The bending radius is 7.5 times the cable diameter, allowing safe bending without damaging the cable. Installation requires adherence to technical specifications to ensure the cable's functionality and service life.

Operational Advantages
The cable offers high mechanical stability and electrical reliability. The PE insulation and layered sheath ensure long service life and protection against environmental influences. The low line attenuation and high insulation quality guarantee clear and interference-free signal transmission. The clear marking of conductors simplifies installation and maintenance. The construction is optimized for use in fixed telecommunications systems, with underground or pipe installation providing a secure and durable solution.

Protection rating, operating voltage, copper conductor, PE insulation, star quad, layered sheath are the central technical features determining the cable's functionality and reliability. The specifications for rated voltage, test voltage, loop resistance, current-carrying capacity, operating capacitance, insulation resistance, capacitive couplings, and line attenuation are crucial for technical evaluation and use in telecommunications.