Further information for Draka Comteq A-2YF(L)2Y 2 X 2 X 0 - A 2YF (L) 2Y 2x2x0 8 ² St III Bd telephone cables underground
Telephone cables for underground water-tight O 2YF (L) 2Y ... St. Vol III to VDE 0816
Application:
The connection cable in local networks and PBX systems for telephony and for the transmission of signals to be laid in suitable ground, in cable ducts and pipes.
Building:
Conductor: solid bare copper conductor
0.6 mm or 0.8 mm diameter
Insulation: PE (2Y)
Core identification: with black rings
Stranding: 4 strands to star quad
5 star quad for basic bundle
each 5 or 10 sub units for
Main units and the and
Main beam to cable core
stranded.Jelly filling Seelenbe- ment shell: aluminum tape laminated sheath = 0.2 mm with plastic beiseitig
and coated with the
PE jacket (black) welded
Sheath Marking: continuous telephone handset and meter marking white
Specifications: 0.6 mm 0.8 mm
Rated voltage: 225 V 225 V
Test voltage: 2000 V 2000 V
Loop resistance: 130 Ohm / km 73.2 ohm / km
Current Rating: 2.5 A 5.1 A
Operating capacity: 52 nF / km 55 nF / km
Insulation resistance: 5 Gx Gx km 5 km
Capacitive coupling K3 (800 Hz, 300 m): 800pF/400pF line attenuation (800 Hz) approx: 1.04 dB / km 0.78 dB / km Temperature range: - 20 ° C - + 50 ° C (during installation)
- 30 ° C - + 70 ° C (after installation)
Bending radius: 10 x cable diameter
Number of pairs + Cable Ø mm ² 2 x 2 x 0.8 Outer diameter approx: 10.0 Cu factor (kg / m%): 2.0 Weight (kg / m%): 10.0 Type: A-2YF (L) 2Y 2 X 2 X 0.8 Quantity: 1 MTR