| General |
| Degree of protection | shielded |
| Category | CAT 6 |
| Link performance class | E |
| Bandwidth | 250 MHz |
| Data rate | 1GBase-T |
| Port count | 8 |
| Connection type | RJ45 |
| Termination type | LSA |
| Wiring diagram | EIA/TIA 568B |
| Rack height | 1 HE |
| Rack depth | 254 mm |
| Voltage withstand | 1000 VDC (contact/contact) |
| Colour | Black |
| Colour code | RAL 9005 |
| Certification | UL, 3P Permanent Link, Channel Link |
| Compliance with standards | ISO/IEC 11801, EN 50173 |
| Grounding terminal | Central |
| Cable clamping | Cable tie |
The DIGITUS Patch Panel DN-91608S is a shielded, 8-port network connection module for mounting in standard racks with a depth of 254 mm (10 inch). It is designed for structured cabling in IT and telecommunications installations and enables central connection points for network cables within the rack. The device is designed for use in professional environments such as server rooms, data centers, or office networks, where reliable and high-quality cabling is required.
Applications
The patch panel is designed for installation in 19-inch racks and is suitable for networks supporting data transfer rates up to 1 Gbit/s (1GBase-T). It is used in structured cabling systems to organize cabling for network devices such as switches, routers, or workstations. Mounting is done at a height of 1 rack unit (1 HE), enabling compact placement in existing rack systems. Cabling is performed via LSA bars, color-coded according to EIA/TIA 568B, to ensure unambiguous assignment of the conductors.
Functions and Features in Detail
The device is designed as a CAT 6 patch panel according to Link Performance Class E, enabling a bandwidth of up to 250 MHz. This specification complies with the standards ISO/IEC 11801 and EN 50173, which apply to the planning and installation of structured cabling systems. The RJ45 sockets (8P8C) are shielded to minimize electromagnetic interference and ensure signal integrity. Shielding is achieved through 360-degree contact, ensuring complete shielding of the contacts. The dielectric strength is 1000 VDC between contacts and 1500 VDC between contact and ground, enhancing electrical safety.
Technology Explained Simply
Cabling is performed via LSA bars, which provide a mechanically stable and electrically reliable connection between the patch panel and the network cables. The color-coded arrangement according to EIA/TIA 568B simplifies installation and maintenance, as the assignment of conductors is unambiguous. The central grounding connection ensures effective shielding of the entire module, which is particularly important in environments with high electromagnetic interference. Mounting includes cable tie mounting points to ensure proper cable routing.
Compatibility and Accessories
The patch panel is designed for use with CAT 6 network cables and supports standards for 1GBase-T networks. It is compatible with the standards ISO/IEC 11801 and EN 50173, which apply to the planning and installation of structured cabling systems. Certification according to UL and 3P Permanent Link as well as Channel Link confirms compliance with international quality standards. It is designed for mounting in racks with a depth of 254 mm (10 inch), enabling universal use in standard rack systems.
Mounting and Installation
Mounting is performed in a 19-inch rack, with the panel installed at a height of 1 HE. Fixing is done via integrated mounting elements, ensuring secure and stable anchoring. Cable connections are made via LSA bars, which provide a mechanically stable and electrically reliable connection. The color-coded arrangement according to EIA/TIA 568B simplifies installation and maintenance.
Operational Advantages
The shielded design and 360-degree shielding contact ensure high signal quality and minimize electromagnetic interference. Certification according to Link Performance Class E and compliance with ISO/IEC 11801 and EN 50173 guarantee a reliable and high-performance network connection. The compact form factor in 1 HE enables efficient use of rack space. The central grounding connection and cable tie mounting points support orderly and maintenance-friendly installation.
The device is finished in black (RAL 9005), enabling visual harmonization with other rack components. Delivery includes the DIGITUS cat.6, Class E patch panel, shielded 8-port.