DEHN 961125, EAN: 4013364118621

DEHN 961125 DB M 1 255 FM surge arrester Type 1

Installation > Grounding Systems > Lightning protection material

DEHN 961125 DB M 1 255 FM surge arrester Type 1

Lieske Part No. 379198
Mfg Part No 961125
EAN-Code 4013364118621
Manufacturer DEHN
Here only 402,51 EUR
478,99 EUR incl. VAT

Further information for DEHN 961125 DB M 1 255 FM surge arrester Type 1

Extended technical data
Max. prospective short-circuit current100 kArms (220 kApeak)
Limitation / Extinction of mains follow currentsup to 100 kArms (220 kApeak)
Max. backup fuse (L) up to IK = 100 kArms (ta ≤ 0.2 s)500 A gG
Max. backup fuse (L) up to IK = 100 kArms (ta ≤ 5 s)315 A gG
Standards
CertificationUL
UL StandardUL 1449 5th edition
UL File NumberE319777
Supplementary data
Nominal discharge current (8/20 µs) (In)50 kA
Technical data
SPD according to EN 61643-11 / IEC 61643-11type 1 / class I
Nominal voltage (a.c.) (UN)230 V (50 / 60 Hz)
Max. continuous operating voltage (AC) (UC)255 V (50 / 60 Hz)
Lightning impulse current (10/350 µs) (Iimp)50 kA
Specific energy (W/R)625.00 kJ/ohms
Voltage protection level (UP)≤ 2.5 kV
Follow current extinguishing capability (a.c.) (Ifi)50 kArms
Follow current limitation / Selectivityno tripping of a 32 A gG fuse up to 50 kArms (prosp.)
Response time (tA)≤ 100 ns
Max. backup fuse (L) up to IK = 50 kArms (ta ≤ 0.2 s)500 A gG
Max. backup fuse (L) up to IK = 50 kAeff (ta ≤ 5 s)315 A gG
Max. backup fuse (L-L')125 A gG
Temporary overvoltage (UT) – characteristic440 V / 120 min. – withstand
Operating temperature range (parallel connection) (TUP)-40 °C ... +80 °C
Operating temperature range (through-wiring) (TUS)-40 °C ... +60 °C
Operating state / fault indicationgreen / red
Number of ports1
Cross-sectional area (L/N, L'/N', N/PE(N)) (min.)10 mm2 solid / flexible
Cross-sectional area (L/N, N/PE(N)) (max.)50 mm2 stranded / 35 mm2 flexible
Cross-sectional area (L'/N') (max.)35 mm2 stranded / 25 mm2 flexible
For mounting on35 mm DIN rails acc. to EN 60715
Enclosure materialthermoplastic, red, UL 94 V-0
Place of installationindoor installation
Degree of protectionIP 20
Capacity2 Standard DIN module, DIN 43880
ApprovalsVDE, KEMA, UL
Type of remote signalling contactchangeover contact
Switching capacity (a.c.)250 V / 0.5 A
Switching capacity (d.c.)250 V / 0.1 A; 125 V / 0.2 A; 75 V / 0.5 A
Cross-sectional area for remote signalling terminalsmax. 1.5 mm2 solid / flexible
Test values according to UL 1449
SPD classification according to UL 1449Component (Type 4) SPD for SPD Type 2 application
Rated A.C. Voltage230 V
Frequency60 Hz
Max. Continuous Operating Voltage (AC) [L-N] (MCOV)255 V
Voltage Protection Rating [L-N] (VPR)1500 V
Amperage (series connection)115 A
Nominal discharge current (8/20µs) ( In)20 kA
Operating Temperature Range-40°C…+85°C
Cross-sectional area (L/N, L'/N', N/PE(N))AWG 8 Cu stranded
Torque (L/N, L'/N', N/PE(N))65 ポンドインチ
Connection of remote signalling contactClass 2 circuits only
Cross-sectional area (remote indicator)AWG 14-22
Torque (remote indicator)3 Lbs-in
Single-pole, coordinated DEHNbloc modular lightning current arrester, type 1 according to EN 61643-11 on a spark gap basis, consisting of a base part and a plugged-in protection module. Maximum system availability thanks to RADAX-Flow follow current limitation. For protecting low-voltage consumer systems against overvoltages, even in the event of direct lightning strikes. For use in the lightning protection zone concept at the interfaces 0A - 1.